1U Rackmount Quick Start Guide
2
Connecting the SCSI and Power Cables
0
1
Shut down and turn off the selected host server. Turn
off all attached accessory devices, such as printers and
other SCSI devices.
2
On the back panel of the 1U Rackmount, connect one
end of the supplied external SCSI cable to either of the
SCSI connectors on the same side of the 1U Rackmount
as the installed tape drive. See
figure 1
.
3
Connect the supplied SCSI terminator to the adjacent
SCSI connector on the back panel of the 1U Rackmount.
See
figure 1
.
4
Connect the other end of the external SCSI cable to the
host.
5
Connect the power cable to the power receptacle on
the back panel of the 1U Rackmount. See
figure 1
.
6
Each SCSI device must have its own unique ID. Change
the SCSI ID if necessary. See
figure 1
.
7
Plug in the power cable to the nearest properly
grounded power outlet.
8
Turn on the power switch on the back panel of the
1U Rackmount.
9
Turn on drive power by pressing the power button on
the front panel of the 1U Rackmount. The green power
LED should illuminate.
10
Turn on any other devices you turned off earlier.
11
Turn on the host server.
Figure 1 Back Panel
Configuration
N
OTE
:
Any time you change the SCSI ID, you must
turn the tape drive power off and then back on
by pressing the power button on the front panel
of the 1U Rackmount.
Power
cable
SCSI cable
SCSI ID
switch
SCSI
Terminator
Installing a Second Tape Drive
0
Follow these instructions to install a second tape drive or to
reinstall a tape drive after it has been removed.
Required Tools
0
#1 and #2 PHILLIPS® screwdrivers
Additional Required
Equipment
0
• (1) Tape drive
• (1) External SCSI cable
• (1) SCSI terminator
Instructions
0
1
Turn off 1U Rackmount drive power by pressing the
power button on the front panel.
2
Turn off the power switch on the back panel of the 1U
Rackmount.
3
Disconnect the power cable from the back panel of the
1U Rackmount.
4
Remove the 1U Rackmount from the the equipment
rack. Place the 1U Rackmount on a clean, stable, flat
surface.
C
AUTION
:
Before performing this procedure, you must
turn off the 1U Rackmount and disconnect it from its
power source.