20

Daily Checks

 

„

With the controller turned off, check the joystick. Make 
sure it is not bent or damaged and that it returns to the 
neutral position when you release it. Check the rubber 
boot around the base of the joystick for damage. Visually 
inspect the boot. Do not handle or try to repair it. See 
your Quantum Rehab Provider if there is a problem.

 

„

Visually inspect the controller harness. Make sure that 
it is not frayed, cut, or has any wires exposed. See your 
Quantum Rehab Provider if there is a problem.

 

„

Check for flat spots on solid tires. Flat spots could 
adversely affect stability.

 

„

Inspect the seating system, armrests, and front riggings 
for loose hardware, stress points, or damage. See your 
Quantum Rehab Provider if there is a problem.

Weekly Checks

 

„

Disconnect and inspect the controller from the power 
base. Look for corrosion. Contact your Quantum Rehab 
Provider if necessary.

 

„

Ensure that all parts of the controller system are securely 
fastened to your power chair. Do not overtighten any 
screws.

 

„

Check for proper tire inflation. Pneumatic tires should be 
inflated to the psi/bar/kPa air pressure rating indicated 
on each tire. If a tire does not hold air, see your Quantum 
Rehab Provider for replacement of the tube.

 

„

Check the brakes. This test should be carried out on a 
level surface with at least 3 feet (1 meter) of clearance 
around your power chair.

To check the brakes:

1.  Turn on the controller and turn down the speed level of 

your power chair.

2.  After one second, check the battery condition meter. 

Make sure that it remains on.

3.  Slowly push the joystick forward until you hear the 

electric brakes click. Immediately release the joystick. 
You must be able to hear each electrical brake operating 
within a few seconds of joystick movement. Repeat this 
test three times, pushing the joystick backward, then left, 
and then right.

Monthly Checks

 

„

Check for drive tire wear. See your Quantum Rehab 
Provider for repair.

 

„

Check the caster wheels for wear. Replace them as 
necessary.

 

„

Check the caster forks for damage or fluttering which 
indicates that they may need to be adjusted or have the 
bearings replaced. See your Quantum Rehab Provider 
for repair.

 

„

Check the entire power chair for loose hardware and 
changes in the function or performance of the power 
chair. See your Quantum Rehab Provider for service or 
repair.

 

„

Keep your power chair clean and free of foreign material, 
such as mud, dirt, hair, food, drink, etc.

 

„

Spring shocks and gas dampers should be visually 
checked for any abnormality, structure damage, or bent 
rods. See your Quantum Rehab Provider for repair.

Yearly Checks

Take your power chair to your Quantum Rehab Provider for 
yearly maintenance, especially if you use your power chair 
on a daily basis. This helps ensure that your power chair is 
functioning properly and helps prevent future complications.

Storage

Your power chair should be stored in a dry place, free 
from temperature extremes. When storing, disconnect the 
batteries from the power chair. See “Batteries and Charging.”

If you fail to store the unit properly, the frame can rust 
and the electronics can be damaged. Any corroded 
electronic connection should be replaced.

Batteries that are regularly and deeply discharged, 
infrequently charged, stored in extreme temperatures, or 
stored without a full charge may be permanently damaged, 
causing unreliable performance and limited service life. It 
is recommended that you charge the batteries periodically 
throughout periods of prolonged storage to ensure proper 
performance.

You may wish to place several boards under the frame of 
your power chair to raise it off of the ground during periods 
of prolonged storage. This takes the weight off the tires and 
reduces the possibility of flat spots developing on the areas 
of the tires contacting the ground.

Disposal of Your Power Chair

Your power chair must be disposed of according to applicable 
local and national statutory regulations. Contact your local 
waste disposal agency or Quantum Rehab Provider for 
information on proper disposal of power chair packaging, 
metal frame components, plastic components, electronics, 
batteries, neoprene, silicone, and polyurethane materials.

Plastic bags are a suffocation hazard. Dispose of plastic 
bags properly and do not allow children to play with them.

Cleaning and Disinfection

 

„

Use a damp cloth and mild, non-abrasive cleanser to 
clean the plastic and metal parts of your power chair. 
Avoid using products that may scratch the surface of 
your power chair.

 

„

If necessary, clean your product with an approved 
disinfectant. Make sure the disinfectant is safe for use 
on your product before application.

WARNING!

WARNING!

CARE AND MAINTENANCE

Summary of Contents for Jazzy 1450 Series

Page 1: ...owner s manual Quantum Jazzy 1450 Series...

Page 2: ...a red circle and red slash Intended Use The intended use of the Pride Mobility Products device is to provide mobility to persons limited to a seated position that have the capability of operating a po...

Page 3: ...Since we recognize that not all English speaking countries use the same words or spellings please refer to the following chart for some common word variations that may be encountered throughout this...

Page 4: ...Location of Rear Cover Location of Trapeze Bars Manual Freewheel Lever Drive Wheel Anti tip Wheel Caster Wheel Front Riggings Foot Platform Shown Seatback Armrest Joystick Controller Seat Base Front C...

Page 5: ...nderstand or if you require additional assistance for setup or operation please contact your Quantum Rehab Provider Failure to follow the instructions in this manual and those located on your power ch...

Page 6: ...specially trained in assisting a power chair user in various daily living activities As you begin using your power chair during daily activities you will probably encounter situations in which you wi...

Page 7: ...f harness Regardless of which type of controller is used the harness must be secured to the seat assembly and not allowed to drag on the floor Motor Connectors This is where the controller connects to...

Page 8: ...r engaged See figure 2 You must turn off the power before disengaging the drive motors otherwise you may get an error code on the controller To clear this code turn off the controller and place the po...

Page 9: ...be necessary to install the seat either prior to initial operation or after transporting your power chair Contour seats are attached to the power base with the Universal Mounting System UMS The UMS c...

Page 10: ...ie down points for the purpose of securing the unoccupied power chair during motor vehicle transport Each tie down is clearly labeled for this purpose To secure a power chair equipped with tie down po...

Page 11: ...with Synergy Seating System ASSEMBLY Figure 8 Unoccupied Transit System Securement Points Front of vehicle Figure 7 Controller Harness Routing on a Contour Seat Wire Ties Wire Ties To Power Base Figu...

Page 12: ...he occupant from the power chair before making any adjustments Youmayneedthefollowingtomakecomfortadjustments metric standard socket set and ratchet adjustable wrench metric standard hex key set threa...

Page 13: ...t You can change each armrest s width independently of the other NOTE Changing the armrest width may increase the overall width of your power chair To change the armrest width 1 Locate the two armrest...

Page 14: ...ided in supplemental manuals provided with your seating system Foot Platform Height Adjustment The foot platform height is easily adjusted to several different heights To raise or lower the foot platf...

Page 15: ...ect the power chair occupant and minimize the likelihood of injury caused by contact with the vehicle during a crash or sudden braking The positioning belt should be secured at all times Never allow t...

Page 16: ...andard electrical outlet PROHIBITED Do not allow unsupervised children to play near the power chair while the batteries are charging Quantum Rehab recommends that you do not charge the batteries while...

Page 17: ...the batteries 3 Give the batteries another full charge of at least 8 to 14 hours and operate your power chair again The batteries will now perform at over 90 of their potential 4 After four or five ch...

Page 18: ...o provide a battery that best suits your power chair s specific demands Fresh batteries arrive regularly at Quantum and are promptly shipped with a full charge During shipping the batteries encounter...

Page 19: ...l General Guidelines Avoid knocking or bumping the controller especially the joystick Avoid prolonged exposure of your power chair to extreme conditions such as heat cold or moisture Keep the controll...

Page 20: ...unction or performance of the power chair See your Quantum Rehab Provider for service or repair Keep your power chair clean and free of foreign material such as mud dirt hair food drink etc Spring sho...

Page 21: ...Be sure that the controller s power is turned off and the power chair is not in freewheel mode before performing this procedure When changing a tire remove only the four lug nuts then remove the wheel...

Page 22: ...l Post Connect Red wire to Red Positive Terminal Posts Connect Black wire to Black Negative Terminal Posts Figure 18 Battery Installation Battery Wiring Diagram Label Front Battery Rear Battery Yellow...

Page 23: ...igure 18 Make sure you tighten the fasteners so that the connections are secure 8 Connect the battery harness to the new rear battery according to the battery wiring diagram See figure 18 9 Install th...

Page 24: ...24 NOTES...

Page 25: ...25 NOTES...

Page 26: ...26 NOTES...

Page 27: ......

Page 28: ...bility co nz UK 32 Wedgwood Road Bicester Oxfordshire OX26 4UL www quantumrehab co uk B V Authorised EU Representative De Zwaan 3 1601 MS Enkhuizen The Netherlands www quantumrehab eu Italy Via del Pr...

Reviews: