Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing Array or Expansion Module Hard Drives
Quantum DXi6902 User’s Guide
165
•
Installing a Replacement Drive in an Array or Expansion Module
Identifying a Failed Drive in an Array or Expansion Module
The DXi6902 Array modules (RBODs) and Expansion modules (EBODs)
each support twelve high capacity (4 TB) hard disk drives (
The Array and Expansion module hard drives are used for data storage.
Figure 98 DXi6902 Array and
Expansion Module Drive Slot
Numbering
Use the indicator LEDs on the hard drive carrier to identify the failed
hard drive (see
•
LEDs off
- No power.
• Drive service action allowed LED (blue)
•
Solid
– It is safe to remove the hard drive from the array for
service.
• Drive fault (amber)
•
Solid
– The hard drive has failed.
•
Blinking
– Drive volume or Array module locate function.
• Drive active LED (green)
•
Solid
– No activity on the hard drive.
•
Blinking
– There is activity on the hard drive.
Note:
If a drive fails, you will be notified by a service ticket in the
remote management console.
HDD Slot 1
HDD Slot 2
HDD Slot 3
HDD Slot 4
HDD Slot 5
HDD Slot 6
HDD Slot 7
HDD Slot 8
HDD Slot 9
HDD Slot 10
HDD Slot 11
HDD Slot 12