Chapter 3: FRU Removal and Replacement Procedures
Replacing a Node Processor and Heatsink
Quantum DXi6900 G2 Field Service Manual
121
Item
Description
6
Back panel slot for RJ-45 connectors
Installing a Replacement Network Daughter Card
To install the replacement network daughter card in the DXi6900 G2 Node:
1. Angle the card so that the RJ-45 connectors fit through the slot in the back panel (see
).
2. Align the captive screws at back end of the card with the captive screw sockets on the system board.
3. Press the touch point on the card until the card connector is firmly seated on the system board
connector.
4. Using a #2 Phillips screwdriver, tighten the two captive screws to secure the network daughter card to
the system board.
5. Replace the quad port SAS card in expansion card riser 2 (see
Replacing an Expansion Card in Riser 2
).
Opening and Closing the Node on page 64
).
Turning On the DXi6900 G2 on page 22
).
8. Run
Factory Detect Hardware
from the
Service Menu
to detect the new hardware (see
).
9. In the remote management console, delete any administrative alerts and close any service tickets.
Replacing a Node Processor and Heatsink
This section describes how to remove and replace a processor (CPU) and heatsink in the DXi6900 G2
Node and contains the following sections:
l
Obtaining a Replacement Processor and Heatsink below
l
Replacing the Processor and Heatsink on the next page
Obtaining a Replacement Processor and Heatsink
Before beginning the replacement procedure, make sure that you have the required replacement kit. The
appropriate replacement processor and heatsink will be provided by Quantum Customer Support (see
).
You will need the following items to perform this procedure:
l
Replacement processor and heatsink kits provided by Quantum Customer Support.