TPA-MHL2-8R
– Quick Start Guide
Page 16
November 20, 2013
Revision B2
Use the procedure below to make the connections for running the compliance tests on an MHL sink device.
1. Apply power to the TPA-MHL2-8R using the power adapter provided.
2. Make the connections as shown in the diagram below. For this application you will be using the section on the
TPA-MHL2-8R labeled
HDMI
MHL
– MHL SINK DUT
.
a. Connect an HDMI cable from an HDMI source device (Quantum Data 980 Video Generator module shown
in the example above) to the
HDMI IN
connector of the
HDMI
MHL
– MHL SINK DUT
block on the TPA-
MHL2-8R.
b. Connect an MHL cable from the
MHL OUT TO DUT
connector on the
HDMI
MHL
– MHL SINK DUT
block of theTPA-MHL2-8R to the MHL sink device under test.
3. If you wish to test 1080p60 you will need to put the TPA into the Packed Pixel mode using either the 980 with the
HDMI Video Generator module or the 882. Refer to the Quantum Data website for the 980 User Guides or 882E
User Guides in order to determine the commands necessary to put the TPA-MHL2-8R into the Packed Pixel
mode.