Use the procedure below to make the connections to the TPA-MHL-8R for running the HDCP
compliance tests on an MHL source device.
1. Apply power to the TPA-MHL-8R using the power adapter provided.
2. Make the connections as shown in the diagram below. For this application you will be using
the section on the TPA-MHL-8R labeled
882 CONNECTIONS
– SOURCE DUT.
a. Connect an MHL cable from the MHL source device under test to the MHL IN FROM
DUT connector on the TPA-MHL-8R.
b. Connect an HDMI cable from the HDMI OUT connector of the TPA-MHL-8R to the
appropriate connector on the Encryption Status Tester (EST) and then to the 882EA
HDMI IN connector.
3. Refer to the 882EA User Guide for details on how to run HDCP compliance tests on a
source device.