- 10 -
below the set temperature in heating mode, and they are
closed above the set temperature in cooling mode
(taking
the switching sensitivity into account). The closed state of the
output terminals No.
1
(NO) and No.
2
(COM) are indicated by
the notice „
HEAT
” (heating) or „
A/C
” (cooling) in the bottom left
corner of the display, according to the selected mode.
3.4. Calibration of the thermometer of the thermostat
You can calibrate the thermometer of the appliance (to correct
measured temperature). To this end all you have to do is change
the position of the orange-colored potentiometer by a Phillips
screwdriver. When you adjust the potentiometer clockwise then
the displayed temperature will be higher than that measured
initially, and when you adjust it anticlockwise the displayed
temperature will be lower than that. The displayed temperature
can be adjusted within a range of approx. 3 °C.
Correction of the displayed temperature takes place a few
seconds after the adjustment.
ATTENTION!
If the modification of the basic settings was done
after inserting the batteries and the modifications did not take ef
-
fect, please press the “
RESET
” button located on the main panel
of the thermostat.