QBOX-100P Series - User Guide, Rev. 1.0
// 33
7.2.
DC Power Connection
The QBOX-100P Series is connected by a 2-pin Phoenix connector (Figure 1, pos. 1) via a DC power supply wiring to a
DC power source.
The QBOX-100P Series is delivered with a power adapter with a 2-pin Phoenix power plug terminal attached as well
as a power cable. The Phoenix plug terminal may be separated from the power adapter depending on ordered
configuration. Users can use the supplied power cord and power adapter to carry AC power from AC power source
and then convert it into DC 12 V. Users can also detach the Phoenix plug terminal from the power adapter and use it to
prepare the connecting wires for DC connection. DC power voltage should be 12 V.
In case the supplied power adapter and Phoenix plug terminal are separated from each
other per your ordered configuration, the white wire of the adapter carries the positive
(+) end while the black one carries the negative (-) end.
Figure 11: Phoenix power plug terminal
1
Slotted pan head screw for securing the wire
2
Slotted pan head screw for securing the Phoenix plug terminal to the Phoenix connector
3
Location for inserting the positive (+) input wire
4 Location for inserting the negative (-) input wire
7.2.1.
Cabling
For the pin assignment Phoenix power plug terminal refer to the subsection 11.1.1 "Phoenix Connector".
1.
Cut the required length two isolated wires ( 1mm2) AWG 18 and strip each end 5 ~ 7 mm.
2.
Twist the striped wire-ends and provide them with ferrules.
3.
Loosen the two slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the
prepared wires.
4.
Insert the wires into the corresponding clamp of the Phoenix plug terminal. Make sure that you have the right
polarity of the connection [refer to Figure 11 or subsection 11.1.1 "Phoenix Connector"].
5.
Fasten the screws to secure the wires into the clamps of the plug terminal.
1
1
2
2
3
4