500300 Rev. U
Menu Operations
4-13
MAINTENANCE
SUB-MENUS
SUB-MENU
FUNCTIONS
COMMENTS
DEFAULT CONFIG.
1
Resets Drive Configuration parameters to defaults
DEF. SCSI CONFIG.
Resets SCSI Configuration parameters to defaults
SCSI ENABLE:
Enable/disable communications to SCSI PCBA
DISPLAY
FIRMWARE
MODEL NUMBER
Displays the tape drive model number
SERIAL NUMBER
Displays the tape drive serial number
EXEC. CPU VERSION
Executive CPU Firmware version and revision date
EXEC. CPU CHECKSUM
Executive CPU PROM checksum in hexadecimal
WRITE DSP VERSION
Write DSP firmware version and revision date
WRITE DSP
CHECKSUMS
Write DSP PROMs checksum in hexadecimal
READ FORMATTER
PART NO.
Displays the part number of the Read Formatter
PCBA
READ DSP VERSION
Read DSP firmware version and revision date (341X
only)
READ DSP CHECKSUMS
Read DSP PROMs checksum in hexadecimal (341X
only)
MOTION CPU VERSION
Motion CPU firmware version and revision date
MOTION CPU
CHECKSUM
Motion PROM checksum in hexadecimal
SCSI VERSION
SCSI CPU firmware version and revision date
SCSI CHECKSUM
SCSI CPU PROM checksum in hexadecimal
PREPARE MEDIA
WRITE 6250 IDENT
Initializes tape with 6250 ID burst (341X only)
WRITE 3200 IDENT
Initializes tape with 3200 ID burst (except
3413/3414)
WRITE 1600 IDENT
Initializes tape with 1600 ID burst
SECURITY ERASE
Erases tape and ID burst from BOT to EOT
VERIFY MEDIA
Checks entire tape for media defects (341X only)
DEMONSTRATION
Used for demos and presentations
DIAGNOSTICS
GENERAL TESTS
Power up diagnostics
WRITE/READ TEST
Tests read and write electronics at all densities
MOTION TEST
Tests tape motion
BOT/EOT TEST
Quick check of BOT and EOT sensors
DISP COMMAND LOG
Displays the 48 most recent interface commands
AC LINE VOLTAGE
Presents a graphic indication of the AC line voltage
SCSI DIAGNOSTICS
SCSI PCBA power up diagnostics
SERVICE
SKEW CHECK
Allows tape to be moved to check read skew
PROM CHANGE
1
See text.
BOARD CHANGE
1
See text.
MOTION CALIBRATE
Recalibrates tape handling and tape sensing circuitry
1
Moving W1 on the WREX PCBA from ON to OFF disables these functions and causes the display to
read
FEATURE LOCKED
.