Model WBP-101
Wireless Pulsewave
Blood Pressure Monitor
INSTRUCTION MANUAL
Page 1: ...Inc New York USA Product Name Wireless Pulsewave Blood Pressure Monitor Model WBP 101 Email sales qualsig com Website www qualsig com Model WBP 101 Wireless Pulsewave Blood Pressure Monitor INSTRUCTIO...
Page 2: ...ce correctly and efficiently please read this Instruction Manual before use In addition please take good care of the manual after your reading to ensure you can find it easily when necessary This prod...
Page 3: ...AUTION It indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property Attention Consultt...
Page 4: ...is not recommended since blood vessels and flow require recovering time for accurate results 6 Do not use the cuff when arm is wet or sweaty 7 Do not subject the monitor or the AC adapter to strong sh...
Page 5: ...o loose so that a finger may be hardly inserted between the cuff and arm Both top and bottom edges should touch evenly around the arm POSTURES 1 Sit in a chair beside a table with your feet on the flo...
Page 6: ...hs please store the device with the battery fully charged SETTING UNITS 1 While the device is powered off press and hold the button for over five seconds to enter unit setting mode The screen should d...
Page 7: ...s the device starts testing pulse wave by releasing the pressure gradually at a constant speed Pressure value decreases and is shown on the screen 6 As soon as measurement is completed the DualCuff de...
Page 8: ...he circle Once pressure reaches the target it will start to release gradually and complete the measurement circle The results are shown on the right 3 Within 60 seconds you may restart a new measureme...
Page 9: ...nual input on the home page as shown below Note that you have to login to your account in order to save data on the Input data page Manually saved data will also be included in the 2D plot described a...
Page 10: ...ill void the product warranty Do not disassemble or attempt to repair the unit and or components 9 Fully charge the battery if the unit will not be used in more than three months TROUBLESHOOTING ERROR...
Page 11: ...Power Supply Any power source DC 5V 200mA Such as USB and phone adapter etc Internal Battery DC 3 7V 850mAH Li ion battery Operating Temperature 5 0 C 40 0 C Relative Humidity 15 RH 80 RH Storage and...