We ask you to carefully read this instruction manual before operating your new coffee machine for the first time. 
Keep these instructions in a safe place where you can consult them when necessary. 
The inappropriate use of this machine exempts Quality Espresso from any liability. 

 

1.2 Safety indications 

 

 

The machine should only be installed by authorized technical personnel. The manufacturer 
declines any liability for possible injuries caused by inappropriate installation. 

 
 

 

The use of gloves and a minimum of two people is recommended to manually move the machine 
to its installation site. 

 
 
 

 

The machine should be stored in areas with a temperature higher than 5º C. 

 

 

In the event of storage or transport of the machine in temperatures lower than 0º C, and in order to 
prevent freezing, the machine’s hydraulic circuit should be emptied first. 

 

 

In the event of freezing, the machine should be placed in an area with a temperature higher than 
10º C to wait for unfreezing. Under no circumstances should the machine be connected to the 
electrical circuit before it is unfrozen.

 

 

 

 

It is recommended that the machine be installed in a spacious area, free of air currents and with a 
solid base. Avoid installing the machine on a wet or hot surface. 

 

 

Regulate the height of the machine with the support legs. Maximum inclination cannot be greater 
than 1º between any of its axes. 

 

 

 

 

Check that all of the electrical connection characteristics comply with the voltage, frequency and 
wattage indications described on the machine’s specification plate. This plate is located on the 
chassis under the drainage tray. 

 
 
 
 
 
 

 

 
 
 

 

 

 

We consider the machine to be installed correctly when it has been connected to a magneto-
thermic omnipolar circuit breaker appropriate to the machine’s power, along with a differential that 
does not exceed a residual current of 30 mA. 

 

 

The machine must be installed in accordance with the current electrical regulations of your area. 
You must make ensure that the electrical installation is reliably grounded in accordance with the 
aforementioned regulations. The company declines any liability for possible injuries caused by a 
defective installation or incorrect ground connection. 

 

 

Extension cords or outlet adapters of any kind should not be used to connect the machine to the 
power supply. The connection cable should never be rolled up, but instead it should be fully 
extended to avoid possible overheating. 

 

 

 

Safety Indications 

   

 

 

   

 

   

 

 

 

 

  1. 

Installation 

Transport 

 

Storage 

Placement 

 

Electrical 
Connection 

 

 

 

WARNING 

May cause injuries. 

   

INFORMATION 

   Important or useful information.  

 

RISK OF FIRE OR ELECTRIC SHOCK 

  May cause injuries. 

 

Summary of Contents for Ruby2

Page 1: ...Ver 27 09 2012 User Manual Before operating this equipment read the instructions for usage and connection R R Ru u ub b by y y2 2 2 Manufacturer of coffee machines since 1952 08548600...

Page 2: ...EDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO DOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY WARNING RISK OF FIRE OR ELECTRIC SHOCK...

Page 3: ...ion 3 2 Installaci n 3 3 Dose Programming 4 Cleaning and Daily Care 4 1 External Cleaning 4 2 Cleaning of Parts 4 3 Daily Care 5 Selecting Pushbutton LED Illumination Mode 5 1 Illumination Modes 5 2 P...

Page 4: ...he machine on a wet or hot surface Regulate the height of the machine with the support legs Maximum inclination cannot be greater than 1 between any of its axes Check that all of the electrical connec...

Page 5: ...used exclusively by adults Children do not recognize the dangers associated with machines hence it should be kept out of their reach or they should be prevented from using it People with physical or s...

Page 6: ...Power Switch 6 Steam Arm 8 Drip tray 7 Feet 9 Drain Tray 10 Boiler Pressure Gauge 12 Hot water Outlet 11 Filter Holder Water Supply Main Water Net Water Pump Pump Rot 8 9 bar Element Wattage 2 500 W...

Page 7: ...3 8 G exit 4 Grounded plug protected with a magneto thermic circuit breaker 5 Water supply tube supplied with machine from water softener 6 Drain tube 7 Water softener 1 3 2 4 5 6 7 2 4 1 It is recom...

Page 8: ...blink indicating a water level warning This warning can be cancelled by turning the machine off and on again i You should not use extension cords or outlet adapters of any kind to connect the machine...

Page 9: ...t the amount of coffee to be ground to single servings since the ground coffee from one day should be discarded the next 2 Rinse the group head with the help of the blind filte 3 Clean the filter and...

Page 10: ...e1 Press the continuous coffee pushbutton to select Mode 2 Press the two coffee pushbutton to select Mode 3 Selecting Pushbutton LED Illumination Mode 5 b LED MODE 2 By default all the pushbuttons are...

Page 11: ...rt Fax 34 933 322 111 www qualityespresso net e mail info qualityespresso net One coffee two coffee keys and LED level indicator blinking Noisy Pump SYMTOMS POSSIBLE CAUSES COMMENTS Blocked pump No wa...