CAUTION: 

IF YOU USE THIS HEATER IN CONJUNCTION WITH A THERMAL 

CONTROL, A PROGRAM CONTROLLER, A TIMER OR ANY OTHER 

DEVICE THAT SWITCHES THE HEATER ON AUTOMATICALLY, 

REMEMBER TO OBSERVE ALL SAFETY WARNINGS AT ALL 

TIMES. THE FIREPLACE HEATER HAS SAFETY OVERHEAT 

PROTECTION. IF THE OVERHEAT PROTECTION TRIPS, SWITCH 

OFF ALL SWITCH BUTTONS AND WAIT APPROxIMATELY 5 -10 

MINUTES. IT SHOULD RESET AUTOMATICALLY ONCE THE UNIT 

COOLS DOWN.

WARNING:  PROCEDURES AND TECHNIqUES IF NOT CAREFULLY 

FOLLOWED WILL RESULT IN DAMAGE TO THE EqUIPMENT AND 

WILL ExPOSE THE USER TO THE RISK OF SERIOUS INJURY, 

ILLNESS OR DEATH. 

This electric fireplace heater is for use on 120 volts. The cord has 

a plug as shown at A in illustration below. An adapter as shown 

at C is available for connecting three-blade grounding-type plugs 

to two-slot receptacles. The green grounding plug extending from 

the adapter must be connected to a permanent ground such as a 

properly grounded outlet box. The adapter should not be used if a 

three-slot grounded receptacle is available. 
A 15 AMP circuit is required to operate this heater. If the breaker 

trips when the heater is used then you may need to move the 

heater to another location or unplug other appliances that are on 

the same circuit. If you require an extension cord use one that is 

rated at 1875 watts. 

ASSEMBLY INSTRUCTIONS
 

PARTS LIST 

qTY

Fireplace insert ....................................................................... 1
A)   Top panel ......................................................................... 1
B)   Base panel ....................................................................... 1
C)   Upper front panel .............................................................. 1
D)   Left front panel ................................................................. 1
E)   Right front panel ............................................................... 1
F)   Left side panel .................................................................. 1
G)  Right side panel ................................................................ 1
R)  Medium KD screws ............................................................3

S)  Wood connectors .............................................................. 8
T)  Short KD screws ............................................................... 5
U)  Mounting Clips .................................................................. 3
V)  Mounting Brackets ............................................................ 2
W)  KD screws ...................................................................... 45
X)  Plastic Connectors .......................................................... 13

Y) SELF REPAIR SET
Touch-up repair paint (bottle)
L-shape bracket...................................................................... 2
Screws for L bracket ............................................................... 8
Plastic connectors ................................................................... 1
KD screws .............................................................................. 3
KD nuts .................................................................................. 3

Z) WALL ANCHOR SAFETY CABLE
Wall anchor ............................................................................ 1
Screw for wall anchor .............................................................. 1
Screw for mantle .................................................................... 1
Safety cable .............................................................................1

TOOL REQUIRED: PHILLIPS HEAD SCREWDRIVER

Summary of Contents for MM910-33ECN

Page 1: ...never the fireplace is left operating and unattended 4 Always unplug fireplace when not in use 5 Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions has...

Page 2: ...the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A 15 AMP circuit is required...

Page 3: ...all panels are assembled Step 1 Attach 13 plastic connectors X to Panel C D E F and G with 26 KD screws W as shown in Fig A 2 KD screws W for each plastic connector Attach 2 wood connectors S to pane...

Page 4: ...ly connected to a grounded electrical outlet it is ready to operate OPERATION BY THE CONTROL PANEL The controls are located behind the 2 front covers at the top right and left corners of the insert an...

Page 5: ...att type E 12 bulbs Step 4 Loosen remove and replace the burnt out bulb s Step 5 Set the log set bed back into place and re attach the screws Step 6 Close the glass window and re attach the screws Ste...

Page 6: ...See Fig G Fig G Fig H 3 Attach the SMALL L BRACKET and lock in place with SCREWS as shown in Fig H CLEANING To clean unit first turn off controls on unit and unplug the unit from power source To clea...

Page 7: ...the unit This warranty is void if in the opinion of Quality Craft the unit has been tampered with altered misused damaged abused or used with the wrong power source Light bulbs are not covered by this...