background image

8

CLEANING

To clean unit first turn off controls on unit and unplug the unit from 

power source. To clean glass display panel; remove dust with clean 

dry cloth or to remove finger prints and other marks clean glass with 

clean damp cloth. Do not use abrasive cleaners or spray liquids on 

glass display panel surface. Metal and metal painted parts should 

be cleaned with damp cloth. Do not use abrasive cleaners or spray 

liquids on these surfaces. 

WARRANTY

Every electric fireplace heater is tested before it leaves the factory 

and it is guaranteed for one year. If the unit should fail to operate 

correctly within one year from the date of purchase, call customer 

service at 1-800-459-4409 (EST). We will, at our discretion either 

repair or replace the unit. It will have to be returned to us freight 

prepaid and we will return the repaired or replaced unit to you 

freight prepaid. The company’s sole obligation is to repair or replace 

the unit. 

This warranty is void if in the opinion of Quality Craft the unit has 

been tampered with, altered, misused, damaged, abused or used 

with the wrong power source. Light bulbs are not covered by this 

warranty. The warranty is for homeowner use only and does not 

cover units used in commercial situations.

Imported by  

quality Craft

Laval, Quebec, Canada  H7S 2G7 

1-800-459-4409 (EST) 

www.qualitycraft.com        

Made in China

Summary of Contents for MM480PG-47CW

Page 1: ...perating and unattended 4 Always unplug fireplace when not in use 5 Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner 6 Do not use outdoors 7 This electric fireplace heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or ...

Page 2: ...nd such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A 15 AMP circuit is required to operate this heater If the breaker trips when the heater is used then you may need to move the heater to another location or unplug other appliances that are on the same circuit If you require an extension cord use one that is rated at 1875 watts...

Page 3: ... B Fig A Fig B Step 3 Attach the LEFT SIDE PANEL G to the LEFT FRONT PANEL E with 2 KD SCREWS R Attach the RIGHT SIDE PANEL H to the RIGHT FRONT PANEL F with 2 KD SCREWS R See fig C Fig C Step 4 Attach the LEFT E G and RIGHT F H SIDE PANELS to the BASE B using 4 KD SCREWS R 2 screws on each side See Fig D Fig D Step 5 Place the UPPER FRONT PANEL C over both FRONT PANELS E and F and lock in place t...

Page 4: ... Fig K and 2 MEDIUM KD SCREWS W and 2 Spacers Q with the MANTEL UNIT as shown in Fig L Fig K Fig L Step 5 Move assembled unit to desired location Unit should not be positioned in an area exposed to direct sunlight WALL ANCHOR SAFETY CABLE The use of WALL ANCHOR SAFETY CABLE is highly recommended in order to reduce the risk of the fireplace being tipped over acci dentally WARNING This CABLE may red...

Page 5: ...ffect The unit will be beep and the indicator light will be ON The bulbs for flame effect log set will be ON To adjust the flame intensity hold down the button the flame optics will go higher or lower Once you have found the desired setting release the button Pressing the button again will stop the light function 750W Press this button for low heat level The unit will beep the pilot light and indi...

Page 6: ...nc or rechargeable Nickel Cadmium batteries MAINTENANCE WARNING Disconnect power and unplug the power cord before attempting any maintenance or cleaning to reduce the risk of fire electric shock or damage to persons The bulbs in your unit can become extremely hot Allow at least 10 minutes between turning off the unit and removing the light bulbs to avoid the accidental burning of the skin RISK OF ...

Page 7: ...oles as shown in Fig B Fig B 2 Drill the holes with diameter 3 4 inches 10 mm and depth 3 4 inches 10 mm on the mantel Each PLASTIC CONNECTOR needs 3 holes See Fig C Fig C Fig D 3 Gently install the KD NUTS into the drilled holes with hammer as shown in Fig D 4 Attach the PLASTIC CONNECTOR and lock in place with KD SCREWS as shown in Fig E Fig E Option 2 Use the SMALL L BRACKETS and SCREWS 1 Place...

Page 8: ...should fail to operate correctly within one year from the date of purchase call customer service at 1 800 459 4409 EST We will at our discretion either repair or replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid The company s sole obligation is to repair or replace the unit This warranty is void if in the opin...