background image

1

01/21

7082-153K

R

TREKKER INSERT PELLET

APPLIANCE

MODEL(S):

TREKKERI-MBK

TREKKERI-PMH

TREKKERI-TWL

Installation Manual

Installation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation.

OWNER: Retain this manual for future reference.

NOTICE: DO NOT DISCARD THIS MANUAL

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

If the information in these instructions is 

not  followed  exactly,  a  fire  could  result 

causing property damage, personal injury, 

or death.

• 

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

• 

Do not over fire - If appliance or chimney connector 

glows,  you  are  over  firing.  Over  firing  will  void 

your warranty.

• 

Comply with all minimum clearances to combustibles 

as specified. Failure to comply may cause house fire.

NOTE:

  To  obtain  a  French  translation  of  this  manual, 

please contact your dealer or visit 

www.quadrafire.com

REMARQUE :

 Pour obtenir une traduction française de 

ce manuel, s’il vous plaît contacter votre revendeur ou 

visitez 

www.quadrafire.com

Check building codes prior to installation.

• 

Installation MUST comply with local, regional, state 

and national codes and regulations.

• 

Consult  local  building,  fire  officials  or  authorities 

having  jurisdiction  about  restrictions,  installation 

inspection, and permits.

CAUTION

WARNING

HOT SURFACES!

Glass and other surfaces are hot during 

operation AND cool down. Hot glass will 

cause burns.

• 

Do not touch glass until it is cooled

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY  SUPERVISE  children  in  same  room 

as fireplace.

• 

Alert children and adults to hazards of high temperatures

• 

High  temperatures  may  ignite  clothing  or  other 

flammable materials.

• 

Keep clothing, furniture, draperies and other flammable 

materials away.

WARNING

Tested and approved for wood pellets only. Burning of 

any other type of fuel voids your warranty. 

CAUTION

Summary of Contents for TREKKERI-MBK

Page 1: ...Failure to comply may cause house fire NOTE To obtain a French translation of this manual please contact your dealer or visit www quadrafire com REMARQUE Pour obtenir une traduction fran aise de ce ma...

Page 2: ...Dimensions 8 B Clearance to Combustibles US CAN 9 C Masonry Chimney and Fireplace Clearances 10 D Minimum Opening for Masonry ZC Fireplaces 10 E Hearth Extension 11 F Floor Protection 11 G Installati...

Page 3: ...fication Number Number 98 17 EPA Certified Emissions 0 74 grams per hour LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 700 to 39 400 hr BTU Input 16 400 to 50 800 hr Vent Siz...

Page 4: ...ntally exiting the room and a smoke CO alarm be installed in the bedroom The size of the room must be at least 50ft per 1 000 Btu hr stove input if the stove exceeds the room size out air must be inst...

Page 5: ...appliance where there will be a clear passage for a Listed chimney through the ceiling and roof vertical or through exterior wall horizontal Installing the required outside air kit will affect the lo...

Page 6: ...rts and articles packed inside the Component Pack Inspect all the parts and glass for shipping damage Report to your dealer any parts damaged in shipment All labels have been removed from the glass do...

Page 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Page 8: ...5 Front View with Basic Surround Panel Set 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 8 2 Front View with Cast Panel Set 23 7 8 in 606mm 32 in 814mm 2...

Page 9: ...be added to this dimension Figure 9 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actu...

Page 10: ...he height from the hearth to the bottom of the mantel is 39 3 4 inches Table 10 1 Minimum Opening Dimensions Inches Millimeters A Height 24 3 8 619 B Front Width Steel Panel Set 32 1 4 819 Front Width...

Page 11: ...f the fireplace with screws or nails stating that the fireplace may have been altered to accommodate the insert and must be returned to original condition for use as a conventional fireplace Figure 11...

Page 12: ...gHTrequirements or if the factory built fireplace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be secu...

Page 13: ...12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of plants...

Page 14: ...mands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to t...

Page 15: ...iance and chimney NOTICE Hearth Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Down drafts Ti...

Page 16: ...llation Figure 16 2 1 Locate the calculated equivalent feet of pipe on the vertical left side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above sea level 3...

Page 17: ...rances carefully for this type of installation to ensure adequate room for outside air venting B Full Reline with Outside Air Vertical Figure 17 2 NOTE Use metal plate around exhaust vent pipe and sea...

Page 18: ...ound exhaust vent pipe and seal all edges with non flammable insulation such as fiberglass mineral wool or ceramic material DO NOT use high temperature cauling materials to seal any edge to prevent fu...

Page 19: ...of house 3 Use wire ties to secure flex pipe to collar assembly 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach flex pipe not included to outside termination cap with second wire t...

Page 20: ...ces 2 cast trim legs and 1 cast trim header underneath the panel set also face down 6 Place washer provided over tab and secure the trim and panel together with screw Continue for all tabs 7 Secure ca...

Page 21: ...s Right Log Figure 21 3 Figure 21 4 F Optional Log Set Instructions 2 PIECE LOG SET INSTALLATION 1 Place the left log as shown There are 2 indentations in the bottom of the log to fit over the screw h...

Page 22: ...n 78db The closer the number is to 0 the better the signal strength Occasionally the signal strength may decrease to as low as 79db which is considered normal However a steady wireless signal strength...

Page 23: ...Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 23 1 7 7 Mobile Home Installation Products of combustion generate carbon monoxide and different fuels generate different l...

Page 24: ...24 01 21 7082 153K Date of Service Performed By Description of Service A Service Maintenance Log 8 8 Refrence Materials...

Page 25: ...25 01 21 7082 153K Date of Service Performed By Description of Service...

Page 26: ...Set 2 Pc Sold as set only LOGS 60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Flue Adapter Required if TPVNT 4 is removed LKADP Surround Std Panel For Cast Trim SP MTVS CST Component Pack 70...

Page 27: ...3 8 x 4 223 0140 Nut Wing 1 4 20 Pkg of 12 226 0110 12 Y Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Washer Sae Pkg of 25 227 0080 25 Y Washer FI 1 4 Black Pkg of 10 1202473 10 Pkg of 50 120...

Page 28: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Reviews: