19
01/21
7082-153K
Abaisser le nivellement
Boulons si nécessaire
pour Conserver le
niveau d'insertion Lors
de l'installation.
Figure 19.2
- OAK Exploded View
A. Leveling System
The leveling bolts are located on the sides of the appliance,
front and rear. To access the bolts, remove the front access
panels. Reach in and turn the bolt to the desired height to
level the appliance
(Figure 19.1)
.
B. Outside Air Kit Instructions
3 INCH (76mm) ALUMINUM FLEX PIPE NOT INCLUDED
1. Measure distance from floor to air vent opening in
appliance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 3-1/2 to 4 inch
(89-102mm) opening on inside wall and a 4 to 4-1/2 inch
(102-114mm) opening on outside of house.
3. Use wire ties to secure flex pipe to collar assembly.
4. Slide trim ring over flex pipe and run pipe through wall.
5. Attach flex pipe (not included) to outside termination cap
with second wire tie
(Figure 19.2)
.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
C. Removal of Cast Sides
Remove the cast side by releasing the upper, spring-loaded
latch
(Figure 19.3)
. Access the latch through the upper
panel vent holes. The cast panel should fall forward. Lift it
out of its lower nest and set the panel aside.
6
6
Appliance Set-Up
Figure 19.1
Lower the leveling
bolts if necessary to
keep the insert level
when installing.
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
•
Enclosed space such as an attic or garage
CAUTION
Figure 19.3
- Shown with Cast Panel Set
Collar
Wire Ties
Trim Ring
Termination Cap
3 inch Aluminum Flex
Pipe (not included)