Quadra-Fire TREKKER Series Owner'S Manual Download Page 32

32

March 17, 2020

7080-166J

Service Parts

R

TREKKER

Beginning Manufacturing Date: Jun 2018 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION

. Parts must be ordered from a dealer or 

distributor. 

Hearth and Home Technologies does not sell directly to consumers

. Provide 

model number and serial number when requesting service parts from your dealer or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

22

Extension Cable USB

SRV7080-171

Y

Battery 3V CR2477

Pkg of 2

SRV7000-869

Y

23

Latch Bracket Assembly

SRV7034-049

Y

24

Vacuum Switch

SRV7000-531

Y

Vacuum Hose

3 Ft cut to fit

SRV7000-373

Y

25

Control Board

SRV7080-052

Y

Wire Harness

SRV7080-129

Y

Fuse 5A, Slow IEC

Pkg of 10

7000-490/10

Y

Wire Harness, Hall Effect

SRV7080-130

Y

26

Side Mount, Right

7034-126

27

Shroud Right

SRV7080-168

28

Combustion Blower

SRV7080-106

Y

Combustion Blower Gasket, Between Housing and Stove

SRV7080-117

Y

Combustion Blower Motor Gasket, Between Motor and Housing

SRV7080-107

Y

29

Flue Collar Assembly

SRV7080-013

30

Exhaust Transition Assembly

SRV7034-139

Gasket, Exhaust

SRV7034-109

31

Bluetooth Key

SRV7080-156

Y

32

Feed Assembly

SRV7080-010

Y

Feed Spring Assembly (Only)

SRV7001-046

Y

Gasket, Feed Motor

SRV7034-144

Feed Motor

812-4421

Y

33

Elbow Catch

7000-393

34

Convection Blower

SRV7080-105

Y

35

Magnetic Switch

SRV7000-375

Component Pack Assembly 

Matte Black

SRV7080-066

Porcelain Black

SRV7080-069

Porcelain Dark Blue

SRV7080-070

Porcelain Frost

SRV7080-071

Porcelain Mahogany SRV7080-068

Sienna Bronze

SRV7080-067

Twilight

SRV7080-072

Paint Touch-Up

Matte Black

812-0910

Porcelain Black

1-00-0022

Porcelain Dark Blue

1-00-0020

Porcelain Frost

1-00-0021

Porcelain Mahogany 855-1450

Sienna Bronze

TOUCHUP-CSB

Twilight

0001285

Additional service part numbers appear on following page.

Summary of Contents for TREKKER Series

Page 1: ...NING If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and li...

Page 2: ...oors tightly closed during operation Keep viewing and ash removal doors tightly closed during operation Conforme la norme ASTM E1509 12 Std Certifi la norme ULC S627 00 Room Heating Pellet Burning Typ...

Page 3: ...Prop65 9 2 Operating Instructions 10 A Fire Safety 10 B Non Combustible Materials 10 C Combustible Materials 10 D Fuel Material and Fuel Storage 10 E Before Your First Fire 11 F Filling the Hopper 11...

Page 4: ...pilots blowers junction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baf...

Page 5: ...ot covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRA...

Page 6: ...blower will run for about 45 seconds wait for it to stop before moving to manual feed 65 72 HEATING 5 From the OFF home screen press and hold the outer ring for 3 seconds to access the main menu 6 Rot...

Page 7: ...A Certification Number Number 98 17 EPA Certified Emissions 0 74 grams per hour LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 to 39 428 hr BTU Input 16 396 to 50 775 hr V...

Page 8: ...used to operate this product wood and the products of combustion of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon m...

Page 9: ...content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoods Fuels with low mi...

Page 10: ...increases heat the blower will increase its output F Filling the Hopper Open the hopper lid by lifting the handle Fill the hopper with fuel Close the hopper lid The unit will not feed with the hopper...

Page 11: ...own existing fuel in the fire pot will continue to burn without the feed motor run ning but the exhaust and convection blowers will remain on until the exhaust has cooled HOT WHILE IN OPERATION KEEP C...

Page 12: ...e before making another adjustment A properly adjusted fire will have a bright active flame pattern that extends out of the fire pot approximately 6 to 9 inches when burning on high A properly adjuste...

Page 13: ...servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the fire pot and remove any jams in the rare event they occur in the f...

Page 14: ...liance Visit www quadrafire com owner resources to view basic troubleshooting FAQs use care videos We recommend annual service by a qualified dealer Cleaning or Inspection Frequency Daily Weekly Month...

Page 15: ...aterials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled O...

Page 16: ...Tools Needed A Shop Vacuum and generic micro cleaning kit flat head screwdriver bottle brush and a ID hose a It is necessary to remove the baffle to gain access to the heat exchanger Figure 16 2 foll...

Page 17: ...ng above the fire pot bottom approximately 1 16 inch 1 59mm or more it means the springs have lost their tension Lost tension cannot keep the floor in the proper position causing ignition problems and...

Page 18: ...lace fan make sure elect connections are fully assembled 11 Cleaning Convection Blower Requires No Lubrication Frequency See chart on page 14 By Homeowner a Be sure the appliance is allowed to cool b...

Page 19: ...e top of the latch up to lock latch into place G Glass Replacement 1 Swing open the face and remove the door from the appliance by lifting the door off of the hinge pins and lay on a flat surface face...

Page 20: ...acing the bottom flange into the opening first then rotate blower up into position 8 When the blower is properly positioned the latch will engage the notch to hold the blower in place Figure 20 1 9 Re...

Page 21: ...ration Check hopper switch wires for integrity Check hopper lid on correctly Check hopper lid magnet is installed Safety snap disc is tripped not functioning Check to make sure convection blower wires...

Page 22: ...haust probe to exhaust blower housing keeping its wire away from hot surfaces Defective probe Replace probe Control board is defective Replace control board Convection Blower fails to shut off Wire sh...

Page 23: ...e termination further from the structure Excessive feeding incorrect air fuel ratio Adjust the tuning see tuning section Unit rumbles consistently during burns Too much fuel Turn tuning down one numbe...

Page 24: ...probe not properly installed Secure exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Igniter chamber plugged with debris Clean igniter chamber 2 Exhaust Probe Fail Not...

Page 25: ...blows its TRIAC that portion of the circuit will remain closed causing the motor on that leg to run continuously at high speed 7 Heat Exchanger The heat exchanger is located behind the baffle and tra...

Page 26: ...ng via screw and clamp It provides sympathetic exhaust temperature feedback to the control board In turn the control board uses this information to adjust its heat output systems for best performance...

Page 27: ...27 March 17 2020 7080 166J Date of Service Performed By Description of Service B Maintenance Log...

Page 28: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 21 23 24 25 26 27 28 29 30 31 32 33 34 35 6 Color SKU No Mfg Dates Matte Black TREKKER MBK 06 18 Porcelain Black TREKKER PBK 06 18 05 19 Porcelain Dark B...

Page 29: ...MH Sienna Bronze 7034 157CSB Twilight 7034 157TWL Gasket Hopper Lid 10 FT 7000 320 10 2 Hinge Pin SRV7034 159 3 Hinge Retainer SRV7034 163 4 Top Matte Black 7034 155MBK Porcelain Black 7034 155PBK Por...

Page 30: ...080 022 12 1 Glass Retainer 7034 136 Y 12 2 Glass Assembly w Gasket 7034 007 Y Gasket Channel 1 8 x 1 1 4 x 10 7000 377 10 12 3 Hinge Female SRV450 2910 12 4 Door Latch Assembly 413 5200 13 Front Face...

Page 31: ...32 Y 17 Intake Shield 7034 224 Y 18 Firepot Riser Assembly Does Not Include Floor Lever Assembly SRV7080 082 18 1 Firepot Assembly SRV7080 083 Y 18 2 Gasket Firepot SRV7034 190 Y 18 3 Spring Pkg of 4...