Quadra-Fire TREKKER Series Owner'S Manual Download Page 13

13

March 17, 2020

7080-166J

What causes my glass to become dirty?

If the glass has white ash build up it is normal and the glass should be cleaned. If it is a black soot build up airflow through 

the unit may be restricted. The most often cause is overdue maintenance and cleaning. See 

Maintaining and Servicing

 

on 

page 14

 and/or make adjustments to the trim control.

How can I get more heat out of the appliance?

The most often cause of diminished heat output is overdue maintenance and cleaning. See 

Maintaining and Servicing

 

on 

page 14

.

What should I do if I smell smoke or there is ash/soot coming from the appliance?

While there will always be some smoke smell from wood burning appliances (including pellet) you should investigate all 

venting to make sure it is sealed properly. Most vent ing requires silicone to seal the seams.

In addition most homes are built very tight today and with exhaust systems can create negative pressure in the home. 

See 

Negative Pressure

 on 

page 15

 of the installation manual

. For ash or soot check the above and the exhaust blower 

housing and seals.

Why would my appliance run fine last winter but not start this fall?

It is possible that the stove was not properly prepared for the Non-burn season; see 

Troubleshooting Guide

 starting on 

page 21

.

Is there a place to lubricate the blowers to quiet them down?

No. The most often cause of noisy blowers is from the impellers becoming dirty over time. See maintenance and service 

section for maintaining and servicing.

What is the metal object with the bend in it that came inside the plastic bag?

It is a clean-out tool used to help clean the fire pot and remove any jams in the rare event they occur in the feed tube.

Why is there a black residue building up on the outside of my home?

Wind can cause this to happen. If the appliance is oper ating correctly very little soot should ever exit the termina tion cap. 

Check to be sure the venting is installed per the owner’s manual and local codes.

Do I need an outside air kit? 

Outside air is required for mobile home installs and in some jurisdictions. Refer to 

Listing & Code Approvals

 on 

page 7

Mobile Home Installation

 on 

page 24

 of the installation manual and 

Appliance Set-up

 on 

page 20

 of the installation 

manual. Also refer to local building codes.

I am seeing sparks coming out of my pipe (termination cap) outside is this safe?

This is normal. As long as clearances to combustibles were followed this is safe.

I have no power to anything. Does this unit have a circuit breaker or fuse or a reset button?

This unit has one fuse on the control board and a resettable snap disc mounted to the feed tube. If the appliance 

overheats then the snap disc can be reset; if the fuse is blown the control board must be replaced.

Can I burn corn in my unit?

No, this appliance is not approved to burn corn type fuel.

Where is the serial # located on my unit?

The serial number is located on the back of the stove.

No pellets are dropping in my fire pot.

See 

Troubleshooting Guide

 starting on 

page 21

.

Contact your dealer for additional information regarding operation and troubleshooting. 

Visit 

www.quadrafire.com

 to locate a dealer. 

P. Frequently Asked Questions

Summary of Contents for TREKKER Series

Page 1: ...NING If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and li...

Page 2: ...oors tightly closed during operation Keep viewing and ash removal doors tightly closed during operation Conforme la norme ASTM E1509 12 Std Certifi la norme ULC S627 00 Room Heating Pellet Burning Typ...

Page 3: ...Prop65 9 2 Operating Instructions 10 A Fire Safety 10 B Non Combustible Materials 10 C Combustible Materials 10 D Fuel Material and Fuel Storage 10 E Before Your First Fire 11 F Filling the Hopper 11...

Page 4: ...pilots blowers junction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baf...

Page 5: ...ot covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRA...

Page 6: ...blower will run for about 45 seconds wait for it to stop before moving to manual feed 65 72 HEATING 5 From the OFF home screen press and hold the outer ring for 3 seconds to access the main menu 6 Rot...

Page 7: ...A Certification Number Number 98 17 EPA Certified Emissions 0 74 grams per hour LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 to 39 428 hr BTU Input 16 396 to 50 775 hr V...

Page 8: ...used to operate this product wood and the products of combustion of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon m...

Page 9: ...content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoods Fuels with low mi...

Page 10: ...increases heat the blower will increase its output F Filling the Hopper Open the hopper lid by lifting the handle Fill the hopper with fuel Close the hopper lid The unit will not feed with the hopper...

Page 11: ...own existing fuel in the fire pot will continue to burn without the feed motor run ning but the exhaust and convection blowers will remain on until the exhaust has cooled HOT WHILE IN OPERATION KEEP C...

Page 12: ...e before making another adjustment A properly adjusted fire will have a bright active flame pattern that extends out of the fire pot approximately 6 to 9 inches when burning on high A properly adjuste...

Page 13: ...servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the fire pot and remove any jams in the rare event they occur in the f...

Page 14: ...liance Visit www quadrafire com owner resources to view basic troubleshooting FAQs use care videos We recommend annual service by a qualified dealer Cleaning or Inspection Frequency Daily Weekly Month...

Page 15: ...aterials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled O...

Page 16: ...Tools Needed A Shop Vacuum and generic micro cleaning kit flat head screwdriver bottle brush and a ID hose a It is necessary to remove the baffle to gain access to the heat exchanger Figure 16 2 foll...

Page 17: ...ng above the fire pot bottom approximately 1 16 inch 1 59mm or more it means the springs have lost their tension Lost tension cannot keep the floor in the proper position causing ignition problems and...

Page 18: ...lace fan make sure elect connections are fully assembled 11 Cleaning Convection Blower Requires No Lubrication Frequency See chart on page 14 By Homeowner a Be sure the appliance is allowed to cool b...

Page 19: ...e top of the latch up to lock latch into place G Glass Replacement 1 Swing open the face and remove the door from the appliance by lifting the door off of the hinge pins and lay on a flat surface face...

Page 20: ...acing the bottom flange into the opening first then rotate blower up into position 8 When the blower is properly positioned the latch will engage the notch to hold the blower in place Figure 20 1 9 Re...

Page 21: ...ration Check hopper switch wires for integrity Check hopper lid on correctly Check hopper lid magnet is installed Safety snap disc is tripped not functioning Check to make sure convection blower wires...

Page 22: ...haust probe to exhaust blower housing keeping its wire away from hot surfaces Defective probe Replace probe Control board is defective Replace control board Convection Blower fails to shut off Wire sh...

Page 23: ...e termination further from the structure Excessive feeding incorrect air fuel ratio Adjust the tuning see tuning section Unit rumbles consistently during burns Too much fuel Turn tuning down one numbe...

Page 24: ...probe not properly installed Secure exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Igniter chamber plugged with debris Clean igniter chamber 2 Exhaust Probe Fail Not...

Page 25: ...blows its TRIAC that portion of the circuit will remain closed causing the motor on that leg to run continuously at high speed 7 Heat Exchanger The heat exchanger is located behind the baffle and tra...

Page 26: ...ng via screw and clamp It provides sympathetic exhaust temperature feedback to the control board In turn the control board uses this information to adjust its heat output systems for best performance...

Page 27: ...27 March 17 2020 7080 166J Date of Service Performed By Description of Service B Maintenance Log...

Page 28: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 21 23 24 25 26 27 28 29 30 31 32 33 34 35 6 Color SKU No Mfg Dates Matte Black TREKKER MBK 06 18 Porcelain Black TREKKER PBK 06 18 05 19 Porcelain Dark B...

Page 29: ...MH Sienna Bronze 7034 157CSB Twilight 7034 157TWL Gasket Hopper Lid 10 FT 7000 320 10 2 Hinge Pin SRV7034 159 3 Hinge Retainer SRV7034 163 4 Top Matte Black 7034 155MBK Porcelain Black 7034 155PBK Por...

Page 30: ...080 022 12 1 Glass Retainer 7034 136 Y 12 2 Glass Assembly w Gasket 7034 007 Y Gasket Channel 1 8 x 1 1 4 x 10 7000 377 10 12 3 Hinge Female SRV450 2910 12 4 Door Latch Assembly 413 5200 13 Front Face...

Page 31: ...32 Y 17 Intake Shield 7034 224 Y 18 Firepot Riser Assembly Does Not Include Floor Lever Assembly SRV7080 082 18 1 Firepot Assembly SRV7080 083 Y 18 2 Gasket Firepot SRV7034 190 Y 18 3 Spring Pkg of 4...

Page 32: ...Right SRV7080 168 28 Combustion Blower SRV7080 106 Y Combustion Blower Gasket Between Housing and Stove SRV7080 117 Y Combustion Blower Motor Gasket Between Motor and Housing SRV7080 107 Y 29 Flue Col...

Page 33: ...01 24 Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Screw Machine Screw 1 4 20 x 5 8 Pkg of 24 220 0440 24 Screw Pan Head Phillips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Washer Sae 10 Pkg of 25 22...

Page 34: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance...

Reviews: