TROUBLESHOOTING
Pilot won’t light
✔
Is a gas shut-off valve turned on?
✔
Is the valve control knob turned to “PILOT”
(See Lighting Instructions, #7, Pg. 55).
✔
Is the valve control knob pushed in? (See Lighting Instructions, #8)
✔
Was the igniter pressed repeatedly? (See Lighting Instructions, #8)
Main Burners Will Not Start
✔
Has the pilot light gone out? (See Lighting Instructions, Pg. 55).
✔
Is the gas control valve turned to “PILOT” or “OFF” ? (See Lighting Instructions).
✔
Is the ON/OFF switch in the “OFF” position? (Turn to “ON”)
✔
Is the remote control working correctly?
(See instruction manual for the remote control).
✔
Is the thermostat disconnected or set too low?
(See Thermostat Operation, Pg. 47).
✔
If LP, is the tank empty?
Remote Control Does Not Turn Unit On / Off
✔
Has the pilot light gone out? (See Lighting Instructions, Pg. 55).
✔
Is the gas control valve turned to “PILOT” or “OFF? (See Lighting Instructions).
✔
Is the ON/OFF switch turned to “OFF”? (Turn the switch to “OFF”)
If the switch is on, unit will remain on.
✔
Is the remote too far away from the fireplace? (Use remote closer to fireplace)
✔
Is the remote control receiver turned “OFF”?
(See instruction manual for the remote control).
✔
Are the remote control batteries dead?
(See instruction manual for the remote control).
Thermostat Does Not Work
✔
Has the pilot light gone out? (SeeLighting Instructions, Pg. 55).
✔
Is the gas control valve turned to “PILOT” or “OFF” ? (See Lighting Instructions).
✔
Is the thermostat set too low? (See Thermostat Operation, Pg. 47).
✔
Is the On/OFF switch turned to “OFF? (Set the switch to “ON”)
If switch is on, unit will remain on. (The switch overrides the thermostat.)
Fireplace Will Not Distribute Heat
✔
Is the fireplace getting electricity? (Check the breaker switch)
✔
Is the fireplace up to temperature? (See Operating Procedures, Pgs. 54-58).
✔
Is Blower operational? (Check Fan Speed control, Pg. 58).