REMINGTON QFP40 Direct Vent FIREPLACE
Page 16
250-4721 JUNE 2001
INST
ALLA
TION
MINIMUM FRAMING DIMENSIONS
❖
The 1/2" stand-offs on the back and sides and 4" stand-offs on the top of the
fireplace separate the fireplace from the framing members (see page 12,
Installation Terminology). These stand-offs may contact the framing mem-
bers but
no
material may be placed between the stand-offs and the framing.
❖
Installation requires a level surface capable of supporting the weight of the
fireplace (240 lbs.) and vent.
❖
Fireplace must be placed directly on wood or non-combustible surface (not on
linoleum or carpet).
❖
HOT WHILE IN OPERATION! Installation location must be out of traffic and
away from furniture and draperies.
NOTE: Framing dimensions shown below reflect an 1/4" overage on top
and 1/8" overage to each side.
Route Gas Line 6 7/16" behind the framing opening (on either side of can).
For hardpipe connection, allow 1 1/4" above the base of fireplace.
Route electrical
line to the right
rear of fireplace.
45 1/2"
19 5/8"
43"
56 1/2"