![Quadra-Fire PELLET INSERT CB1200I Owner'S Manual Download Page 9](http://html.mh-extra.com/html/quadra-fire/pellet-insert-cb1200i/pellet-insert-cb1200i_owners-manual_768975009.webp)
R
R
R
February 3, 2010
7014-188B
Page 9
CB1200-I Pellet Insert
NOTE:
•
Illustrations reflect typical installations and
are FOR DESIGN PURPOSES ONLY
.
•
Illustrations/diagrams are not drawn to
scale.
•
Actual installation may vary due to
individual design preference.
B. Clearance To Combustibles, UL and ULC
12 in.
(305mm)
Rear Shroud
6 in.
(152mm)
Shown with Hopper Extended
Optional Outside
Air
Combustible
Mantel
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Optional Outside Air
Figure 9.1
Figure 9.2
AS A BUILT-IN
B
D
C
E
B
C
A
0 INCH (0mm) CLEARANCE TO ExPOSED SECTION AND FACE TRIM
Rear Shroud Kit is Required for Built-In Installation
A
Top of Shroud
Top Vent
3.0
76
Rear Vent
0
0
B
Sides of Inside Shroud
Top or Rear Vent
0
0
C
Back of Inside Shroud
Top Vent
2.5
64
Rear Vent
0
0
D
Vent Pipe to Combustible
Top or Rear Vent
3.0
76
Fire Risk.
WARNING
Failure to comply may cause house fire.
Comply with all minimum clear
-
ances to combustibles as specified.
NOTICE:
Please note that while the minimum clear
-
ance for the termination cap is 6 inches
(152mm) there is the possibly of soot
buildup around the termination area. If this
occurs we suggest to move the termination
further away from the house to prevent it.