Programmable Wall Thermostat Installation
How to Install Your Programmable Wall
Thermostat
1. Separate the body of the thermostat from the mounting
plate by gently pulling the two pieces apart
2. Connect your thermostat wire to the W and R terminals
(see fi gure below)
3. Screw the backer plate to the wall using the hardware
included
4. Snap the thermostat to the backer plate
NOTE:
See installation manual for instructions to
connect thermostat wire to your appliance.
The kit comes standard with a wall thermostat and 25’ of
wire. If you need to run more than 25’ make sure you use
a continuous strand of 18 to 22 gauge thermostat wire. For
optimum performance your thermostat should be located on
an inside wall approximately 5’ up from the fl oor.
PROGRAMMABLE THERMOSTAT
PART: WALL-STAT-P
W R
Saturday and Sunday can be programmed individually
by changing the format from 5-2 to 5-1-1. To change
the format :
1. Press and hold the up button and the center button
until the display changes.
2. Press up or down to change system function num-
ber to 16.
3. Press
NEXT
to advance to next function.
4. Press up or down to change status number to 1.
5. Press
DONE
to exit and save settings.
The thermostat maintains a desired room temperature.
The 5-2 day programmable function allows one program
for week days and a separate program for Saturday/Sun-
day. (Up to 4 periods per day).
Programming Thermostat
Thermostat Controls
Function buttons
Press to select the function
displayed just above each
button. (Functions change
depending on the task.)
Digital display
Temperature buttons
Press up or down to set preferred
temperature.
Hold Button
Press to override
programed tem-
perature control
Figure 22.1