January 8, 2016
7080-132J
15
MT. VERNON E2
This pellet heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this pellet heater in a
manner inconsistent with operating instructions in this manual.
3
Maintenance and Service
B. Quick Reference Maintenance Chart
NOTICE:
These are recommendations. When burning high ash content pellet fuel or a corn/pellet
mix you may need to clean the fi repot several times a day. Clean the stove and fi repot
more frequently if you encounter heavy build-up of ash at the recommended interval or you
see soot coming from the vent.
Not properly cleaning your appliance on a regular basis
will void your warranty
.
Shock and Smoke Hazard
• Smoke spillage into room can occur if appliance
is not cool before unplugging.
• Risk of shock if appliance not unplugged before
servicing appliance.
CAUTION
Follow the detailed instructions found in this
section for each step listed as referenced in
the chart below
.
When properly maintained, your appliance will give you
many years of trouble-free service.
Contact your deale
r to
answer questions regarding proper operation, troubleshoot-
ing and service for your appliance. Visit www.quadrafi re.
com to locate a dealer. We recommend annual service by a
qualifi ed dealer.
A. Proper Shutdown Procedure
Turn dial control to OFF, let appliance completely cool and
exhaust blower must be off. After cooling unplug appliance
before servicing.
Cleaning or Inspection
Frequency
Daily Weekly Monthly
Yearly
Firepot
As needed
OR
X
Ash Removal from Firebox
About 5 bags of fuel depend-
ing on ash build-up
OR
X
Glass
When clear view of fi repot
becomes obscure
OR
X
Hopper
Every ton of fuel (50 bags)
OR
X
Exhaust Path, Drop Tube and Behind
Baffl es
Every ton of fuel (50 bags) or
more frequently
OR
X
Door Handle & Gasket Inspection
Prior to heating season
OR
X
Blower, Convection
Every ton of fuel or more fre-
quently depending on perfor-
mance
OR
X
Blower, Exhaust
Every ton of fuel or more fre-
quently depending on perfor-
mance
OR
X
Firebox - Prepare for Non-Burn Season
At end of heating season
OR
X
Venting System
Every 3 tons of fuel or more
frequently depending on per-
formance
OR
X