![Quadra-Fire GB40I Installation & Operating Instructions Manual Download Page 12](http://html.mh-extra.com/html/quadra-fire/gb40i/gb40i_installation-and-operating-instructions-manual_768953012.webp)
March 2000
Page 12
GB 40 I - FIREPLACE INSERT
Fig. E
Tan Thermo Wires
White
Black
Red
On/Off Switch
Fan Speed Switch
Self Adhesive Wire Clip
Thermostat Connection Block
Trim Wiring Plug
Power Cord Ground
Strain Relief
Power Cord
Fig. D
Fig. F
Side Panel
Panel Clamp Bolt
Panel Clamp
Fig. A
Fig. B
Panel Clamp
Bolts
Fig. C
L bracket
NST
ALLA
TION:
PANEL & TRIM
PANEL/TRIM INSTALLATION
NOTE: PANEL AND TRIM MUST BE INSTALLED BEFORE BRICK
1. Slide side panels in between panel clamp and back of insert, see Fig. A. Slide top panel over side panels
and attach with screws provided. Tighten panel clamps by the bolts located in the firebox, see Fig. B.
2. Assemble trim set with the L brackets provided, see Fig. C. Slide trim over panel set. Connect trim
wiring plug to the connector located on the right side of the insert body, see Fig. D. Insert brass trim
screw to panels.
3. Plug wire ends into on/off switch and blower speed control switch as shown in Fig.E.