3
250-3692 (11/2000) DVi32 Gas Insert
SAFETY LABEL
(found behind gas supply access panel
on left-hand side of stove)
1445 North HIghway
Colville, WA 99114
Report #061-S-16-5
October 1999
ANSI Z21.88a-1998
CSA 22.33a-M98 and CAN1 2.17-M91
MODEL: DVI-32 NG
DVI-32 LP
VENTED GAS FIREPLACE HEATER
SERIAL NO.
DVI-32
DVI-32
For use with Natural Gas
For use with Propane
†0-2000'
†0-2000'
Manifold Pressure
3.5"WC
10.0"WC
Minimum Inlet Gas Supply Pressure
4.5"WC
11.0"WC
Maximum Inlet Gas Supply Pressure
7.0"WC
14.0"WC
BTU Input Rating (High)
32,000BTUH
32,000BTUH
BTU Output Rating (High)*
26,800BTUH
27,808BTUH
BTU Input Rating (Low)
20,000BTUH
25,000BTUH
BTU Output Rating (Low)*
16,800BTUH
21,725BTUH
Minimum Efficiency**
78.8%
82.9%
Orifice Size
#33
#51
*Minimum Vent, Blower Off
**Maximum Vent, Blower On
†This appliance equipped for altitudes 0-2000' (0-610M) in USA: and in Canada for altitudes of 0-4500' (0-1370M).
This appliance must be installd in accordance with local codes, if any, if , not follow ANSI Z223.1/
CAN 1-149.
This vented gas fireplace is not for use with air filters.
Install and use only in accordance with manufactaurer’s installation and operating instructions.
Not for use with solid fuel.
Keep burner and control compartment clean. See installation and operating instructions accom-
panying this appliance.
Due to high surface temperatures, keep children, clothing and furniture away.
ELECTRICAL SUPPLY: 120 Volts, 1.2 Amps, 60 Hz
WARNING: Operation of this appliance when not connected to a properly installed and main-
tained venting system can result in carbon monoxide (CO) poisoningand possible death.
G
H
J
C
I
A
B
NOTE:
When installing in a zero clearance
fireplace, the top edge of the panel
set cannot contact combustibles
Minimum clearances to combustible materials from stove body:
A
Side wall to combustibles
9” (229mm)
B
Height of combustible above bottom of insert
29 1/2” (749mm)
C
Height of mantel above bottom of insert
35 1/2” (902mm)
G
Width of mantel
14” (356mm)
NOTE: For every 1" of mantel depth, add 1" to clearance “C”.
NON COMBUSTIBLE HEARTH EXTENSION
H
Height of hearth
0”
1”
2”
3”
5”
I
Depth of hearth
24”
23”
22”
15”
0”
J
Width of hearth
30”
MANUFACTURED
AS A:
DVI-32 NG
DVI-32 LP
f i r e - p a r t s . c o m