VENTING INSTRUCTIONS
PLEASE NOTE:
In order to comply with applicable codes and product warranties, only Simpson Dura-Vent venting
components may be used. DO NOT USE FIELD-FABRICATED VENTING COMPONENTS.
The Quadra-Fire DVI-32 is approved to be vertically terminated in a masonry fireplace or a zero clearance fireplace
with Simpson Dura-Vent GS series and flex pipe. Only Simpson Dura-Vent components labeled and listed in this
section may be used.
IMPORTANT
Read all these instructions carefully before starting the installation. Failure to follow instructions
may create a fire or other safety hazard, and will void the warranty. Be
sure to follow these
installation instructions for venting and clearance to combustible requirements, which may vary
from one installation to another.
INSTALLATION PRECAUTIONS
The Quadra-Fire DVI-32 is an engineered product that has been designed and tested. The warranty will be voided,
and serious fire, health, or other safety hazards may result from any of the following actions: installation of any
damaged venting component, unauthorized modification of the venting system, installation of any component part
not approved by Aladdin Hearth Products, or installation other than as instructed by
these instructions. Consult your
local building codes before beginning this installation.
WARNING:
Always maintain the required clearances (air space) to nearby combustibles to avoid creating a fire
hazard. Do not fill air
space with insulation. Minimum clearance between vent pipes and combustible surfaces is
1”, except where stated otherwise. Use only a Simpson Dura-Vent flex system in masonry fireplaces or metal zero-
clearance fireplaces. Be sure to check the vent termination clearance requirements from decks, windows soffits,
gas regulators, air supply inlets and public walkways, as specified in these installation instructions and local building
codes.
The gas appliance and vent system must be vented vertically to the outside of the building, and never be attached
to a chimney serving a separate solid fuel or gas-burning appliance. This direct vent gas appliance must use its
own separate vent system. Common vent systems are prohibited.
SAFETY PRECAUTIONS FOR THE INSTALLER
Wear gloves and safety glasses for protection when installing this appliance. Exercise extreme electrical caution
when using ladders or on rooftops. Be aware of electrical wiring locations in walls and ceilings.