Quadra-Fire DISCOVERY-II-C Owner'S Manual Operation & Care Download Page 2

2

7033-353G

08/21

1

7033-354

SERIAL RATING PLATE

1

7.75

9.5

LISTED ROOM APPLIANCE, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD . 

"For Use with 

Solid Wood Fuel Only"

 / APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE COMBUSTIBLE SOLIDE, POUR USAGE 

DANS LES MAISONS MOBILES. (UM) 84 HUD. 

"Pour Usage Avec Bois Solide Seulement"

PREVENT HOUSE FIRES / PRÉVENTION DES FEUX DE MAISON

Install and use only in accordance with manufacturer's installation and operating instructions. Contact local building or fire 

officials about restrictions and installation inspections in your area. Do not obstruct the space beneath appliance. 

WARNING 

- For Mobile Homes:

 Do not install in a sleeping room. An outside combustion air inlet must be provided and unrestricted 

while unit is in use. The structural integrity of the mobile home floor, ceiling and walls must be maintained. The appliance 

needs to be properly grounded to the frame of the mobile home. Components required for mobile home installation: Outside 

Air Kit, Part Number OAK-ACC. 

Refer to manufacturer's instructions

 and local codes for precautions required for passing 

chimney through a combustible wall or ceiling and maximum offsets. Inspect and clean chimney frequently - Under Certain 

Conditions of Use, Creosote Buildup May Occur Rapidly. Do not connect this unit to a chimney serving another appliance. 

Optional Blower, Part BK-ACC. Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz. Route power cord away from unit. Do not route 

cord under or in front of appliance. 

DANGER: Risk of electrical shock.

 Disconnect power supply before servicing. Replace 

glass only with 5mm ceramic available from your dealer. Do not use grate or elevate fire. Build wood fire directly on hearth. 

Do not overfire - if appliance or chimney connector glows, you are overfiring. Operate only with the fuel loading door closed. 

Open only to add fuel to the fire. / Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. 

Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil. 

AVIS - Pour Les Maisons Mobiles :

 Ne pas 

installer dans une chambre à coucher. Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué 

lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit être 

maintenue intacte. L'appareil de chauffage doit être fixé à la charpente de la maison mobile. Les composants requis pour 

l'installation des maisons mobiles: Assemblage d'air extérieur, Numéro de Pièce OAK-ACC. 

Référez vous aux instructions

 

du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond 

combustibles, et les compensations maximums. Inspectez et nettoyez la cheminée fréquemment. Sous certaines conditions, 

il se peut que la créosote s'accumule rapidement. Ne pas connecter cet appareil à une cheminée servant un autre appareil. 

tVentilateur Optionnel, Pièce BK-ACC. Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz. Éloignez le fil électrique de 

l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. 

DANGER : Il y a risque de décharge 

électrique.

 Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre 

céramique de 5 mm disponible chez votre fournisseur. N'élevez pas le feu. Bâtissez le feu de bois directement sur l'âtre. Ne 

pas surchauffer. Si l'appareil de chauffage ou le tuyau de cheminée rougissent, vous surchauffez. Opérez l'appareil 

seulement lorsque la porte de chargement est fermée. Ouvrez la porte seulement lorsque vous devez ajouter des 

combustibles dans le feu.

CAUTION

:

 

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 particulate emission standards using crib wood at 

1.9

 G/HR 

This wood heater needs periodic inspection and repair for proper operation. Consult the 

owner’s manual for further information. It is against federal regulations to operate this wood 

heater in a manner inconsistent with the operating instructions in the owner’s manual.

2021

2022

Dec.

Nov.

Oct.

Sept.

Aug.

July

June

May

Apr.

Mar.

Feb.

Jan.

2023

FLOOR PROTECTION:

Floor protector must be a 3/8 (9.5mm) inch min. thickness, 

non-combustible material or equivalent, extending beneath 

heater and to front/sides/rear as indicated on the diagram 

below. 

Exception:

 Non-combustible floor protections must 

extend beneath the flue pipe when installed with horizontal 

venting and extend 2 inches (51mm) beyond each side.

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS 

AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS.

VENT SPECIFICATIONS: / SPÉCIFICATIONS DE LA VENTILATION :
SINGLE WALL:

 Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances. 

MUR SIMPLE :

 De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, 

ou une cheminée de briques, avec espaces libres référés.

DOUBLE WALL:

 Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  a masonry chimney and the referenced clearances. / 

MUR DOUBLE :

 De six (6 inches) 

(152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée de briques, avec espaces libres alloués.

MOBILE HOME:

 Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a spark arrestor.  Apply double wall clearances below when installing unit. / 

MAISON MOBILE :

 Utiliser 

un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur double comme mentionné ci-bas.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters) / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:En Pouces & (millimètres)

NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar. / REMARQUE : Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de l'entrée du conduit.

7033-354E

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

PROTECTION DU PLANCHER:

Le protecteur de plancher doit être d'un minimum de 3/8 

inch (9.5mm) d'épaisseur, de matériel incombustible ou 

équivalent, s'étendant du dessous de l'appareil de 

chauffage à l'avant, aux cotés et à l'arrière comme indiqué 

sur le diagramme suivant. 

Exception :

 Les protections 

incombustibles du plancher doivent s'étendre en dessous 

du conduit de cheminée lorsqu'installées avec une 

ventilation à l'horizontale et s'étendre de 2 inches (51mm) 

de chaque côté.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Manufactured by:

Fabriqué par :

CANADA

203mm (8")

203mm

(8")

203mm

(8")

457mm (18")

1243mm

(49")

minimum

1041mm (41") minimum

Made in U.S.A. 

of US and imported parts. 

/ Fabriqué aux États-Unis-d’Amérique par 

des pièces d’origine américaine et pièces 

importées.

31M-ACC-C

DISCOVERY-II-C

352 Mountain House Road, 

Halifax, PA 17032

www.quadrafire.com

Serial No. / N° de série

HF

BARCODE LABEL

TESTED TO:/ TESTÉ À :

ASTM E2515, ASTM E2780, UL 1482-11 (R2015), ULC S627-00.

R

3100 ACC Series-C

Report / Rapport

0061WS066S

0061WS066E

16" from glass

8"
USA

Fuel loading door

Millennium 31-5/8" Min

39”

minimum

INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP / INSTALLATION : ENTIÈREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE 

A  B 

C  D E  F  G  H

Discovery-II-C

 

18.25 (464) 

11.75 (298) 

28.5 (724) 

16 (406) 

8 (203) 

20 (508) 

48 (1220) 

12 (305)

31M-ACC-C

 

18.25 (464) 

11.75 (298) 

28.5 (724) 

16 (406) 

8 (203) 

20 (508) 

48 (1220) 

12 (305)

DOUBLE WALL PIPE / CONDUIT DU MUR DOUBLE

Discovery-II-C

 

13.5 (343) 

6.5 (165) 

25 (635) 

13 (330) 

6.5 (165) 

18.5 (470) 

48 (1220) 

9 (229)

31M-ACC-C

 

13.5 (343) 

6.5 (165) 

25 (635) 

13 (330) 

6.5 (165) 

18.5 (470) 

48 (1220) 

9 (229)

INSTALLATION:  90° ELBOW OFF TOP OF STOVE THROUGH BACKWALL / INSTALLATION:  90° DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIÈRE

SINGLE WALL PIPE / CONDUIT DU MUR SIMPLE

Discovery-II-C

 

15 (381) 

8.5 (216) 

25 (635) 

13 (330) 

8 (203) 

20 (508) 

48 (1220) 

12 (305)

31M-ACC-C

 

15 (381) 

8.5 (216) 

25 (635) 

13 (330) 

8 (203) 

20 (508) 

48 (1220) 

12 (305)

DOUBLE WALL PIPE / CONDUIT DU MUR DOUBLE

Discovery-II-C

 

11 (279) 

4.5 (114) 

20.5 (521) 

8.5 (216) 

6.5 (165) 

18.5 (470) 

48 (1220) 

9 (229)

31M-ACC-C

 

11 (279) 

4.5 (114) 

20.5 (521) 

8.5 (216) 

6.5 (165) 

18.5 (470) 

48 (1220) 

9 (229)

INSTALLATION: ALCOVE

 - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a 

spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove clearances. / 

INSTALLATION : ALCÔVE

 - Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de 

raccordement à double paroi avec UL103 HT ** cotée Classe usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de 

48 pouces (1219mm) et les dégagements en alcôve référencés.

DOUBLE WALL PIPE / CONDUIT DU MUR DOUBLE

Discovery-II-C

 

14.75 (375) 

8.25 (210) 

26.5 (673) 

14.5 (368) 

N/A 

N/A 

48 (1220) 

*

31M-ACC-C

 

14.75 (375) 

8.25 (210) 

26.5 (673) 

14.5 (368) 

N/A 

N/A 

48 (1220) 

*

*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Factory-built chimney. / *Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650°C cheminée bâtit en usine.

* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED / VOIR LE FABRICANT POUR LES ESPACES LIBRES DES CONDUIT - PAS TESTÉ

90° OFF TOP 

UP & OUT CEILING CLEARANCE

ESPACE LIBRE DU DESSUS DE 

L'APPAREIL AU PLAFOND AVEC 

90°  DE COURBURE 

STOVE TO CEILING CLEARANCE

ESPACE LIBRE DU POÊLE AU 

PLAFOND 

G

G

H

G

A

B

ALCOVE SIDE VIEW / 

VUE DE CÔTÉ DE 

L'ALCÔVE

B

G

A

ALCOVE TOP VIEW /

VUE DU HAUT DE 

L'ALCÔVE 

C

D

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ 

A

B

C

D

CORNER INSTALLATION/

INSTALLATION DU COIN 

E

F

E

F

SAMPLE

Serial

 No.

Safety & 

Emissions  

Test 

Report 

Name

Test Lab & 

Report No.

Mfg. Date

A. Sample of Serial Number / Safety Label 

LOCATION:  Back of appliance

NOTE:

 Clearances may only be reduced by means approved by the regulatory 

authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Model 

Numbers

Summary of Contents for DISCOVERY-II-C

Page 1: ...ed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause h...

Page 2: ... solides ou une cheminée de briques avec espaces libres référés DOUBLE WALL Six inch 6 inches 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103HT Class A chimney or a masonry chimney and the referenced clearances MUR DOUBLE De six 6 inches 152mm de diamètre le connecteur du conduit d air isolé pour mur double avec une cheminée bâtit en usine UL103HT de ...

Page 3: ...ons 7 D Glass Specifications 8 E Mobile Home Approved 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions A Over Firing Your Appliance 9 B Wood Selection Storage 9 C Burning Process 9 D Air Controls 10 E Using Burn Rate Air Control ACC System 11 F Burn Rates and Operating Efficiency 12 G Building A Fire 13 H Blower Operating Instructions 14 I Opacity Smoke 14 J Clear Space 15 K Nega...

Page 4: ... earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances and 10 years from the beginning date of warranty coverage for wood and pellet appliances These time p...

Page 5: ...r forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 interruptions or fluctuations of electrica...

Page 6: ... KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The appliance is ready for normal operation Warning Risk of Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of s...

Page 7: ...rtified Emissions 1 9 grams per hour LHV Tested Efficiency 78 3 HHV Tested Efficiency 72 5 EPA BTU Output 13 900 to 29 100 hr Peak BTU Hour Output 51 000 Vent Size 6 inches Firebox Size 2 cubic feet Recommended Log Length 16 inches Fuel Seasoned Cordwood 20 moisture Weighted average LHV Low Heating Value efficiency using Douglas Fir dimensional lumber and data collected during EPA emission tests i...

Page 8: ...e maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile home installation Improper installation adjustment alteration service or maintenance can cause injury or property da...

Page 9: ...s been an increasing concern about air quality Much of the blame for poor air quality has been placed on the burning of wood for home heating In order to improve the situation we at Quadra Fire have developed cleaner burning wood appliances that surpass the requirements for emissions established by our governing agencies These wood appliances like any other appliances must be properly operated in ...

Page 10: ...us and if we choose to use wood to heat our homes we should do so responsibly To do this we need to learn to burn our appliances in the cleanest way possible Doing this will allow us to continue using our wood appliances for many years to come D Air Controls Users will need to find their preferred setting between high and low based on desired heat output installation configuration and fuel type 1 ...

Page 11: ...nob is located under the high position Figure 11 1 2 Maximize Heat with The ACC System To maximize heat output with the ACC timer System or also known as high burn push the ACC Air Control lever towards the back of the appliance and leave This combined with having the main burn rate control lever pushed up will deliver the most amount of air needed to achieve the highest amount of heat output Figu...

Page 12: ...ce to HI then pull forwards towards the front of the appliance until the knob stops At that point move the Burn Rate Air Control spring handle to 1 2 high 4 High burn setting Burn Rate Air Control spring handle up to high position Also activate ACC timer system knob pushed back to the HI position NOTE The above information is provided as a guideline only Altitude and other circumstances may requir...

Page 13: ...d several full length logs 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 Set the Burn Rate Air Control and activate the ACC timer system 8 When ready to reload It is best to fully open both the Burn Rate Air and Start u...

Page 14: ...Initial cold start up and all Burn Settings The blower can be plugged in and turned on right away The blower fan is turned on and off by a snap disc When your appliance has reached a certain temperature the blower will turn on and when your appliance has cooled down to a certain temperature it will turn off Switch on blower control must be set to auto for this feature to work 2 The blower is equip...

Page 15: ...urnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed K Negative Pressure J Clear Space Figure 15 1 Maintain 4 ft 1 ...

Page 16: ...the speed is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible de...

Page 17: ...very four 4 cords of wood The chimney and chimney cap must be inspected for soot and creosote every two months during the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m measured from bottom of appliance This will prevent pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or ...

Page 18: ...onnector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be removed to reduce the risk of a chimney fire 2 Disposal of Ashes Frequency When ash is within 1 3 4 in 44mm of firebox lip By Homeowner WARNING Fire Risk Prevent creosote buildup Inspect chimney connector and...

Page 19: ...glass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated Operating the appliance with the Burn Rate Air Control and Start Up Air Control all the way open for 30 45 minutes should remove the built up coating CAUTION Handle glass assemb...

Page 20: ...each other in the front WARNING Fire Risk Firebox damage due to improper baffle placement is not covered by warranty Operate the wood burning appliance with the baffle in the correct position only Not doing so could result in Reduced efficiency Overheating the chimney Overheating the rear of the firebox Poor performance Ensure correct baffle placement and replace baffle components if damaged or mi...

Page 21: ...Height Rise and Run on page 13 of the Installation manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Selection Storage on page 9 Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire on page 13 Flue blockage such as birds nests or leaves in terminatio...

Page 22: ...ble or counter top with padding or towels Protect your hands and wear gloves to prevent injury 3 Remove the door with the broken glass by lifting the door up and off of the hinges 4 Lay door face down on a table or counter making sure the handle hangs over the edge so the door lays flat on a soft surface 5 Remove the screws from each glass retainer and remove the glass If screws are difficult to r...

Page 23: ...the spade connectors Replace with new snap disc and re connect to spade connectors 5 Push the snap disc and spade connectors back inside bracket and re attach the bracket to the appliance Figure 23 2 D Door Handle Assembly Service Part SRV7033 071 1 Slide door handle through door 2 Install additional washer s as shown in Figure 23 2 3 Install key in groove 4 Align groove in latch cam with key slid...

Page 24: ...all the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 24 3 and Figure 24 4 5 To re install the ceramic blanket it is easier to fold it in half first Place on top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 24 3 and Figure 24 4 Figure 24 ...

Page 25: ...s 1200 degree F high temp paint Tile Panel Installation 2 Remove tile frame from side by lifting up and pulling away from appliance Figure 25 3 reference solid side panel removal 3 Stack non combustible material tiles in tile frame as shown in Figure 25 2 4 Reattach tile frame Figure 25 4 WARNING Fire Risk Use only noncombustible materials as a decorative tile The appliances are being shipped with...

Page 26: ...pace In order to replace the tube channel assembly a clearance of 19 inches 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the appliance will have to be disconnected from the chimney to proceed with the tube replacement NOTE Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them R...

Page 27: ...27 7033 353G 08 21 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service ...

Page 28: ...28 7033 353G 08 21 Date of Service Performed By Description of Service ...

Page 29: ...ervice Parts DISCOVERY II C R Beginning Manufacturing Date June2017 Ending Manufacturing Date Active Part number list on following page 07 21 Wood Stove 18 1 2 3 4 5 9 10 13 12 11 14 21 15 17 16 20 19 6 7 8 B Exploded View ...

Page 30: ...amic Fiber Blanket 1 2 Thick 832 3390 6 Baffle Protection Channel SRV7033 298 7 Tube Support Rack SRV7033 148 8 Brick Retainer SRV7033 149 9 Baffle Board Pkg of 2 SRV7033 209 10 Tube Channel Assembly SRV7033 023 11 Tube Channel Top SRV7033 237 Y 12 Rear Channel Assembly 7033 002 Y 13 Firebrick Set Complete Set SRV7033 006 13 1 Brick Uncut 9 x 4 1 2 x 1 1 4 Qty 12 Req Pkg of 1 832 0550 Pkg of 6 832...

Page 31: ... 16 Door Assembly Black DR 31 43BK FH Nickel DR 34 43NL FH 16 1 Hinge Pin 1 2 Black 7000 606 2 Nickel SRV430 5320 16 2 Rope Door 3 4 x 84 7 Ft 832 1680 Y 16 3 Door Glass Assembly SRV7000 012 Y Gasket Glass Tape 3 4 x 1 8 5 Ft 832 0460 Y 16 4 Glass Frame Set 4 pcs 832 0350 16 5 Screw Flat Head Phillips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 17 Door Handle Assembly SRV7033 071 17 1 Fiber Handle SRV7060 ...

Page 32: ...8 2 Spring Handle 1 4 Nickel 250 8340 Y 18 3 Door Gasket 7033 282 Y 18 4 Timer Air Control Assembly SRV7033 052 Y Rear Air Door Assembly SRV7033 024 18 5 Control Arm Assembly Rear Air SRV7033 079 18 6 Knob SRV7000 343 18 7 Air Control Rod Guide SRV7033 210 18 8 Latch Magnet SRV229 0631 18 9 Timer Arm Assembly SRV7033 034 Y 18 10 Timer Only Replacement Assembly SRV480 1940 Y 19 Panel Assembly Side ...

Page 33: ...470 Y Wire Harness Blower 7033 262 Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly SRV7033 039 Outside Air Shield SRV33271 Y Outside Air Cover Plate Assembly SRV7033 041 Y FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1 Pkg of 10 25221A 10 Y Button Head 1 4 20 X 5 Pkg of 20 32328 20 Y Nut 2 Wy Side Lock Jam 3 Pkg of 24 226 0100 24 ...

Page 34: ... maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 Notes Th...

Reviews: