Quadra-Fire • COLBAY-INS • 7002-109 Rev. N • 8/10
A
B
C
Figure 9.5
C. Valve Regulator Replacement
Remove upper and lower back shield. Loosen the set col-
lars on the extension rods with the 3/32 in. Allen wrench.
Remove the rods and adapter cap.
Turn control knob to the OFF position, ensure that gas
supply to the valve has been turned off. Using a Torx
TH20, or slotted screwdriver, remove the three pressure
regulator mounting screws (A), pressure regulator tower
(B), and diaphragm (C).
Ensure that the rubber gasket (D) is properly positioned
and install the new HI/LO pressure regulator assembly to
the valve using the new screws (E) supplied with the kit.
Tighten screws securely. (Reference torque = 25 in./lb.)
Install the enclosed identifi cation label (F) to the valve
body where it can be seen.
Fill out the conversion label and attach it to the valve
cover.
Fire Risk.
Explosion Risk.
•
Disconnect any electrical cords and turn
off gas supply to unit before proceeding if
converting fuel on an appliance already fully
installed.
WARNING
Figure 9.6
WARNING
Fire Risk.
Explosion Risk.
•
If the information in these instructions is
not followed exactly, a fi re, explosion or
production of carbon monoxide may result
causing property damage, personal injury or
loss of life.
•
The qualifi ed service agency is responsible
for the proper installation of this conversion
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer’s
instructions supplied with the kit.
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
• Rubber gasket must be seated properly on
valve face.
• Do no install a valve or regulator that has
been dropped.
E
D
F