25
Quadra-Fire • COLBAY-INS • 7002-109 Rev. N • 8/10
NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.
ON/OFF Switch
• An ON/OFF switch is included with appliance and should
be attached to surround/facing.
• If desired an additional wall switch, thermostat, or remote
control may be added to system as shown in Figure
10.1).
• If using a thermostat use one compatible with a millivolt
gas valve system:
- Install the thermostat in the location as indicated in the
thermostat instructions to ensure proper operation of
appliance.
- Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
- Keep wire lengths short as possible by removing any
excess wire length.
- Use the following chart for wire sizing.
A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
10
10
Electrical Information
Figure 10.1 Standing Pilot Ignition Wiring Diagram
ROCKER SWITCH / WALL THERMOSTAT / REMOTE
VARIABLE REGULATOR
PILOT ADJUSTMENT CAP
MANIFOLD PRESSURE
INLET PRESSURE
PUSH BUTTON IGNITOR
THERMOPILE
IGNITOR
PILOT
THERMOCOUPLE
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
Wire Size
Max. Length
16 gauge
65 feet
18 gauge
40 feet
20 gauge
25 feet
22 gauge
18 feet
B. Standing Pilot Ignition System Wiring
• The standing pilot ignition system wiring
DOES NOT
require a 110 VAC supply to operate.
• A 110 VAC junction box may be installed for use of a fan
or remote control. Keep wire lengths short as possible.
The supplied power cord may be routed out onto the
hearth to a nearby outlet.