Page 4
7014-145
May 9, 2008
R
Tools Needed:
Shop Vac and Phillips head screwdriver
1200 Pellet Stove
1.
Lift the hopper lid to access the cleaning rods. Both
black bent handle pull rods are located close to the face
of the appliance to the left and right side.
Figure 4.1.
2.
Pull the rods straight out until they stop, approximately
0 inches (508mm).
. To clean, slide the rods OUT and IN a couple of times.
A. Cleaning the Heat Exchanger Chambers
Heat Exchanger Cleaning Rods
Figure 4.1
1. Open the upper right side panel door and then open
the glass door.
. The baffles are located at the top inside of fire
-
box.
. Place your hand on the baffle and slide it up and the
bottom edge will fall down and then you can lift the
baffle out. Repeat for the other side.
4. Re-install in reverse order.
B. Remove Baffle to Access Heat Exchanger
Tubes and Firebox Exhaust Exits
Exposed Heat Exchanger Tubes
Drop Tube
1.
Use a Shop Vac to vacuum any fly ash and soot from the
heat exchanger tubes and firebox area.
Figure 4.2
.
. Remove any debris that may be in the drop tube.
C. Vacuum Heat Exchanger Tubes, Firebox Area
and Drop Tube
Figure 4.2
D. Clean Exhaust Exit Behind the Exhaust Blower
1. Open both the upper and lower right side panels.
Figure 4.3
.
. Using a Phillips head screwdriver remove the 4 screws
from the clean-out plate and set aside.
Figure 4.3.
. Use a small vacuum hose attachment to clean area.
Figure 4.4
.
4. Re-attach clean-out plate and close side panels.
Clean-Out Plate Removed
Exhaust Blower
Clean-Out Plate
Remove 4 Screws
Open Right
Side Panels
Figure 4.3
Figure 4.4