E. Chimney and Exhaust Connection
1.
Chimney & Connector
: Use 76mm to102mm diameter
type "L" or "PL" venting system. It can be vented vertically
or horizontally.
2.
Residential:
The 76mm vertical Top Vent Adapter Kit and
the 76mm to152mm Top Vent Offset Adapter are tested to
use 24 gauge single wall flue connector or Listed double
wall flue connector to Class A Listed metal chimneys, or
masonry chimneys meeting International Conference of
Building Officials (ICBO) standards for solid fuel appli
-
ances.
3.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
4.
Exhaust Venting
System
: Secure to the appliance with
at least 2 screws 180 degrees apart. Also secure all con
-
nector pipe joints with at least 3 screws through each joint.
5. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
6. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-
sible. Seal pipe joints with high temperature silicone (260°C)
minimum rated only. Do not put silicone inside of pipe.
Vent surfaces get HOT, can cause burns if
touched. Non-combustible shielding or guards
may be required.
WARNING
WARNING
ONLY use connector:
• Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
• Attic or roof space
• Closet or similar concealed space
• Floor or ceiling
Maintain minimum clearances to combustibles
Fire Risk.
Follow Chimney Connector Manufacturer’s
Instructions for Proper Installation.
CAUTION
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVICING ANOTHER APPLIANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
May allow flue gases to enter the house