July 19, 2012
7038-201
Page 5
R
5700 Step Top ACC Wood Burner
CORNER POSITIONING (45°)
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
With Double
Flue Shield
Fitted
A
Min. clearance from firebox to corner walls
100
B
Min. distance from firebox to floor protector front
450
C
Min. distance from rear wall to floor protector front
1443
D
Min. floor protector projection from wall
841
E
Min. overall floor protector depth
1615
F
Min. floor protector front width
850
CORNER POSITIONING (45°)
Drawing not to scale
Table 2
Fig. 4
FIREBOX INSTALLATION
1. If a separate floor protector is being used position now. Place the firebox on the floor protector to
suit the minimum installation clearances. (See Fig 3 or 4).
2. Seismically restrain the firebox and the floor protector to the floor.
3. Fit 2 x 6mm fixings suitable for the floor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
C
A
D
C
A
B
E
F
D