background image

 14 

      7047-910J 

   

January 

13, 

2020

5100 Insert ACC

• 

Must meet minimum standards of 

NFPA 211

.

• 

Must have at least 5/8 inch (16mm) fire clay lining 

joined with refractory cement.   (Installations into a clay 

flue without a stainless steel liner may reduce draw 

which affects performance, will cause the glass to 

darken and produce excessive creosote).

• 

The masonry wall of the chimney, if brick or modular 

block, must be a minimum of 4 inches (102mm) 

nominal thickness.

• 

A chimney of rubble stone must be at least 12 inches 

(305mm) thick.

• 

Cross-sectional area shall conform to 

NFPA 211-2006 

Section 12.4.5.1

.

• 

Should be lined with a 6 inch (152mm) stainless steel 

flue liner to improve performance and reduce creosote 

build-up.

I. Masonry Chimney

UL 1777 Insulated Stainless Steel 

Liner or Other Approved Lining System 

Follow Manufacturer’s Instructions 

on Insulation and Support 

For Zero or Other Non-Code Clearances, 

Follow Approved Liner Manufacturer’s Specific 

Insulation Requirements:  Different Clearances 

May Require Different Specifications 

Masonry Chimney Must 

Have Structural Integrity 

UL 1777 Insulated Stainless Steel 

Liner or Other Approved Lining System 

Minimum 8 in. (203mm) Masonry 

Thickness in Front of Smoke Chamber

Damper Plate Removed or 

Fastened in Open Position 

Seal with Non-Combustible Material 

Minimum Clearance in Accordance 

with Insert Listing 

Floor Protection in 

Accordance with Insert 

Listing 

Follow Manufacturer’s 

Instructions for Maximum 

Liner Extension Above 

Chimney 

Maximum 30

 

Degrees 

Offset in Chimney 

Combustible Floor 

Figure 14.1

NOTE:

 In Canada, this fireplace insert must be installed 

with a continuous chimney liner of a 6 inch 

(152mm) diameter extending from the fireplace 

insert to the top of the chimney.  The chimney 

liner must conform to the Class 3 requirements 

of 

CAN/ULC-S635

, Standard for Lining Systems 

for Existing Masonry or Factory-Built Chimneys 

and Vents, or 

CAN/ULC-S640

, Standard for 

Lining Systems for New Masonry Chimneys.

Generic Insert Model Shown in Illustration

This insert conforms with the 

UL 1482 and ULC S628 

(Canada)

 in all respects, and is approved to 

UL & 

ULC safety standards

 for installation and use within 

a fireplace with a masonry chimney in accordance with 

NFPA 211 and CAN/CSA-B365-01

.

• 

An equivalent liner must be a listed chimney liner 

system or other approved material.

• 

No dilution air is allowed to enter the chimney.

a. 

Secure the fireplace damper in the open position.  

If this cannot be accomplished, it will be necessary 

to remove the damper.

b.  Seal damper area of chimney around chimney 

connector with a high temperature sealant or seal 

insert against the face of the fireplace.

c. 

Both methods must be removable and replaceable 

for cleaning and re-installation.

• 

When possible, install an airtight clean-out door to the 

rear of the smoke shelf.

Summary of Contents for 51I-ACC-BK

Page 1: ...as specified Failure to comply may cause house fire NOTE To obtain a French translation of this manual please contact your dealer or visit www quadrafire com Pour obtenir une traduction fran aise de c...

Page 2: ...rculating Masonry 15 K Prefabricated Metal Chimney 15 L Ovalizing Round Stainless Steel Liners 16 M Altering The Fireplace 16 N Zero Clearance Fireplace 16 5 Appliance Set Up 17 A Outside Air Kit Inst...

Page 3: ...hted average HHV efficiency using Douglas Fir dimensional lumber and data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and...

Page 4: ...ance without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such...

Page 5: ...draft should be approximately 10 inch W C Measure the W C at 6 inches 152mm above the top of the appliance after one hour of operation at each burn setting B Draft Check building codes prior to instal...

Page 6: ...2 3 4 in length 6 or 8 self drilling screws Fire Risk Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomplete c...

Page 7: ...appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this c...

Page 8: ...mm 29 1 8 in 740mm 17 5 8 in 448mm 13 1 8 in 333mm Figure 8 5 Side View with Steel Surround and Optional Offset Adapter OFFSET ADAPT Figure 8 4 Side View with Steel Surround Figure 8 2 Front View with...

Page 9: ...pth 17 7 8 454 B Clearances to Combustibles United States and Canada UL and ULC In Canada a full length 6 inch 152mm S635 flue liner required as per ULC S628 In USA a minimum 5 ft length 1 82m 6 inch...

Page 10: ...eat transfer R value is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being...

Page 11: ...arm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wi...

Page 12: ...there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12 2 Must h...

Page 13: ...configuration the greater the likelihood it may affect performance Chimney height may need to be increased by 2 3 per each 1000 feet above sea level It is not recommended to use offsets or elbows at...

Page 14: ...nimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Off...

Page 15: ...with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Combustible Floor Airtight Insulated Clean Out Stainless Steel Chi...

Page 16: ...Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Inspect the existing fireplace and chimney for any dam...

Page 17: ...fireplace is sufficient to feed the 4 inch flex 4 After sliding can into fireplace feed flex into cut opening to obtain outside combustion air 5 Level outer can and install appliance 6 Remove 4 bolts...

Page 18: ...Appliance Dimensions page for the amount of distance this accessory can telescope between the flue collar and stove pipe liner 1 Remove the cast iron flue collar from the appliance and flip it upside...

Page 19: ...the surround set 6 Install the surround set and trim set to the outer can Place the hook in the surround sides over the surround attachment screws 2 on each side Figure 19 5 7 Place top on top of app...

Page 20: ...ons tat are made to the snap disc Disconnect the wires that attach to the snap dis Figure 20 4 8 Using pliers pry on the tabs that retain the harness enough to remove the harness Do not disconnect the...

Page 21: ...13 2020 7047 910J 21 5100 Insert ACC Figure 21 1 Figure 21 2 Remove Control Plate Remove Strain Relief Disconnect Wires to theSnap Disc Figure 21 3 Figure 21 4 Place Harness Under Tabs Figure 21 5 Fig...

Page 22: ...t metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to sc...

Page 23: ...tside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used It must be equipped with...

Page 24: ...24 7047 910J January 13 2020 5100 Insert ACC A Service and Maintenance Log Date of Service Performed By Description of Service 7 Reference Materials...

Page 25: ...January 13 2020 7047 910J 25 5100 Insert ACC B Accessories List...

Page 26: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this applianc...