3100 ACT Wood Stove Series
Page 8
250-6103C December 6, 2004
R
FLOOR PROTECTION:
Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as
indicated. The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from
sparks and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient.
In US installations,
it is necessary to install a floor protector of 3/8" (10mm) thick metal clad millboard or equivalent at least 16"
(406mm) in front of glass door and 8" (203mm) to both sides of the fuel loading door. Open the door and measure 8” (203mm)
from the side edge of the opening in the face of the stove.
See *exception below.
I
n Canada,
similar floor protection must be provided 18" (457mm) in front and 8" (203mm) from the sides and rear of the
stove.
See *exception below.
*EXCEPTION:
Non-combustile floor protections must extend beneath the flue pipe when installed with horizontal venting
and extend 2” (51mm) beyond each side.
FLOOR PROTECTION
USA - 3100 Millennium
USA - 3100 Uni-Body Step Top
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
Millennium
1232mm
(48-1/2")
minimum
1032mm (40-5/8)
minimum
Millennium
978mm (38-1/2")
minimum
Step Top Uni-body
Step Top
1245mm
(49")
minimum
Must extend 2" (51mm) beyond each
side of pipe (shaded area)
optional coverage
optional
coverage
26-1/4"
48-1/2"
optional
coverage
USA
37-7/8”
required coverage
16"
31-5/8
"
26-3/4"
26-3/4"
optional coverage
optional
coverage
26-1/4"
49.0"
optional
coverage
USA
37-7/8”
required coverage
16"
31-5/8
"
26-3/4"
26-3/4"
3. Set top heat shield on stove and push down
into “S” clips.
4. Install chimney pipe through the hole in the top
heat shield.
TOP HEAT SHIELD INSTALLATION,
Part: 831-0972
INSTALL TOP HEAT SHIELD TO REDUCE REAR CLEARANCES - 3100 Millennium Only
16" from glass
8"
USA
Fuel loading door
4-1/2"
3-1/2
"
31-5/8"
minimum
37-7/8"
minimum
USA - 3100 Millennium
USA -3100 Uni-Body Step Top
1. Unscrew and remove the rear heat deflector.
2. Attach the two “S” clips to the upper edge of the outer
wall of the stove.
Canada - Both Models
Horizontal Venting
Both Models
NOTE: Drawings are for illustration purposes only and are not to scale.
16" from glass
8"
USA
Fuel loading door
3-7/16"
4-9/16
"
31-5/8"
minimum
37-7/8"
minimum
USA: Required
Canada: Recommended