Quadra-Fire 3100 Series Operating & Maintenance Instructions Download Page 18

3100 ACT  Wood Stove Series

Page 18

250-6103C   December 6, 2004

R

(Cut-away 

view)

FRONT 

COVER

SIDE 

COVER (2)

4" (102mm) FLEX LINE 

(Not Included)

FLEX 

FLANGE

OUTSIDE AIR TERMINATION CAP

(contains rodent screen)

FIBERGLASS 

SEALING 

ROPE

Included in Kit:

 1 front cover; fiberglass rope; 2 vent 

straps;  venting  flange  &  4  screws;  termination 

cap  &  screws.    Not  all  materials  are  needed  for 

each model.  

Items Needed for Installation

: 4” (102mm)  flex pipe 

in  the  length  as  required  for  your  installation; 

Phillips  screwdriver;  Silicone  sealant;  Drills  and 

saws necessary for cutting holes through the wall 

or flooring in your home.

1.  Remove all materials from packing box.

2.  Using  a  #2  Phillips  screwdriver,  remove  2  bolts 

beneath the ashcatcher.  Re-use bolts to install front 

cover.  Be certain that the cover is pushed back as 

far as possible.  

3.  Install side covers to each side. Slide covers into 

area and secure with 4 sheet metal screws.

4. 

Floor  installation:

  Cut  a  4”  (102mm)  minimum 

hole in the floor to accommodate outside air piping.  

Use 4” (102mm) metal flex or rigid piping to directly 

connect outside air to the unit or into 

vented

 crawl 

space. 

(Do not put flex into a non-vented crawl 

space)

. Use the supplied termination cap with a 

rodent  screen.    Seal  between  the  floor  and  the 

pipe with silicone to prevent moisture penetration.  

Install  fiberglass  sealing  rope  under  each  side 

of pedestal.

5. 

Rear/wall installation:

  (Millennium Model only, 

use the knockout plate in rear of the pedestal for 

exterior wall venting.)  Cut a 4” (102mm) hole in 

outside  wall  to  accommodate  outside  air  piping.  

Use 4” (102mm) metal flex or rigid piping to directly 

connect  outside  air  to  stove  intake.    Use  the 

supplied  termination  cap  with  a  rodent  screen.  

Seal between the wall and the pipe with silicone 

to prevent moisture penetration.  Install fiberglass 

sealing rope under each side of pedestal.

OUTSIDE AIR KIT INSTALLATION

Part  831-1780

UNI-BODY 

PEDESTAL MODEL

FRONT COVER

SIDE COVER 

(2)

FLEX FLANGE 

(if needed for rear exit.)

4" (102mm) FLEX LINE 

(Not Included)

OUTSIDE AIR 

TERMINTATION CAP

(contains rodent screen)

FIBERGLASS SEALING ROPE

4-3/8" (111mm)

CL

FRONT 
COVER

SIDE 

COVER (2

)

4" (102mm) FLEX LINE

(Not Included)

OUTSIDE AIR TERMINATION 

CAP

(contains rodent screen)

FLEX 

FLANGE

UNI-BODY LEG MODEL

Summary of Contents for 3100 Series

Page 1: ...red condition Close the air controls completely by pulling them out until the glowing has stopped OVERFIRING VOIDS YOUR WARRANTY 4 Cool ashes should be disposed of carefully using a metal container 5...

Page 2: ...are old fashioned when it comes to craftsmanship Each unit is meticulously fabricated and gold and nickel surfaces are hand finished for lasting beauty and enjoyment Our pledge to quality is completed...

Page 3: ...ing Instructions 20 21 Building a Fire 20 Opacity 21 Burn Rates 21 Wood Selection 21 Blower Operation 21 MAINTENANCE Creosote Removal 22 Chimney Cleaning 22 Ash Disposal 22 Over ring 22 Firebrick 22 G...

Page 4: ...6 152mm listed high temperature UL 103 HT or ULC S629M chimney Components required by manufacturers for installation such as the chimney support base firestop as appropriate attic insulation shield i...

Page 5: ...UNI BODY LEG MODEL C L 24 5 8 625mm 9 1 4 235mm 12 5 16 313mm 15 1 16 383mm 14 15 16 379mm 10 15 16 278mm 19 1 16 484mm 18 1 4 464mm 21 0 533mm 34 1 16 357mm Back of stove to glass 10 1 2 267mm 20 1 4...

Page 6: ...und the chimney This space around a chimney is necessary to allow natural heat removal from the area Insulation in this space will cause a heat buildup which may ignite wood framing NOTE Clearances ma...

Page 7: ...le Wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or a masonry chimney Mobile Home must be equipped with a spark arrestor Maximum depth of Alcove shall be no more...

Page 8: ...Top CANADA 203mm 8 203mm 8 203mm 8 457mm 18 Millennium 1232mm 48 1 2 minimum 1032mm 40 5 8 minimum Millennium 978mm 38 1 2 minimum Step Top Uni body Step Top 1245mm 49 minimum Must extend 2 51mm beyo...

Page 9: ...ture that is within 10 305cm of the chimney measured horizontally See 2 10 3 Rule below These are safety requirements and are not meant to assure proper ue draft We recommend using a minimum total sys...

Page 10: ...iner 5 8 16mm Minimum or Equivalent Sill support Header Wood Stud 2 51mm Clearance from chimney wall Fireclay liner 5 8 16mm Minimum or Equivalent The ue should be checked to determine that it is not...

Page 11: ...speci ed by its manufacturer It may be necessary to cut the wall studs and install a header and a sill frame to maintain the wall support The hole in the chimney must have at least an 8 203mm diameter...

Page 12: ...st the chimney Install the trim collar on the outside of the opening Check to make sure there is a 1 25mm air space between the connector and the chimney section During installation be certain that a...

Page 13: ...up which may ignite the ceiling joists The other method is to install an exterior chimney that runs up the outside of the residence Figure 13B This method of installation requires at a minimum a wall...

Page 14: ...n Canada this appliance must be connected to a 6 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS Floor protection referenced on page 8 must be followed 8 Use...

Page 15: ...open ash removal door and replace ash drawer with the overhanging lip facing toward you 7 Close ash removal door securely ARS OPERATING AND CLEANING FIGURE 15A 4 Using a rubber mallet install plugs su...

Page 16: ...Head socket or wrench from the adapter and save 5 Secure mounting brackets to the bottom of the stove with 1 4 20 Phillips screws These screws are located on the outer skin at the bottom rear of the s...

Page 17: ...trol 3 Adjust the speed so the blower runs slowly but does not stop Turn clockwise to slow the blower and counterclockwise to increase the speed The blower speed control for this unit is adjusted at t...

Page 18: ...m metal ex or rigid piping to directly connect outside air to the unit or into vented crawl space Do not put ex into a non vented crawl space Use the supplied termination cap with a rodent screen Seal...

Page 19: ...e wood gives off ammable gases which burn above the fuel with bright ames During this stage of burning it is very important that the ames be maintained and not allowed to go out This will ensure the c...

Page 20: ...some vapor rise from the stove surface this is normal We recommend that you open a window until the odor dissipates and paint is cured NOTE Stove should be run full open for 15 minutes a day to keep a...

Page 21: ...uld be left off until a good burn is established then turned on at a medium or high rate 4 Low burn setting The blower tends to cool off the stove If you are using wet wood or a very low burn setting...

Page 22: ...he door glass This air ow washes the glass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be owing over the glass and the smokey relatively cool cond...

Page 23: ...e top of the bottom bricks Slide top of bricks under clip on back of rebox wall and push bottom of brick back 5 Install side bricks Slide top of brick under clips on side of rebox and push the bottom...

Page 24: ...bustion processes can be frustrating If your reason for removing the baf e is simply to clean the chimney you have alternatives which will save time and effort Call a quali ed chimney sweep or an auth...

Page 25: ...see page 21 832 3401 Ceramic Blanket 1 thick eld cut to t size 14 1 4 x 19 1 2 832 2670 Component Pack includes paint pedestal oak trim gold spring handles and manual 832 0540 Door Handle Assembly 83...

Page 26: ...ifold Tubes 4 13 Oak Trim for Pedestal 2 14 Pedestal Base 1 11 2 3 4 5 6 7 8 9 10 12 13 14 EXPLODED VIEWS Item Part Name 1 Door Cast 2 Door Handle 3 Glass Replacement 4 Glass Frame Assembly 5 Glass Fr...

Page 27: ...years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable ite...

Page 28: ...5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019099 6048195...

Reviews: