17

September 9, 2019

7033-350E

31M-ACC-C

B. Door Handle Assembly

Figure 17.1

Install spring handle using a counter-clockwise motion until 

the spring  handle has a 2 inch clearance from bend of door 

hand rod 

(Figure 17.1).

1.  Locate bolts supplied with the blower.

2. 

Align holes in mounting flange of blower with bolt holes 

in appliance. Blower should be positioned at bottom of 

rear outer skin as shown in Figure 17.2

3.  Re-insert and tighten bolts, securing blower onto outer 

wall of appliance.

4.  Place the bracket containing the snap disc and magnet 

under the bottom left rear corner.

See Owner’s Manual for detailed operating instructions for 

the blower and snap disc.

Figure 17.2

MANUAL: 

Over-rides 

the Snap 

Disc 

AUTO: Fan 

will turn 

ON/OFF 

Automatically 

by the Snap 

Disc

Controls 

the Fan 

Speed 

Snap Disc 

Bracket  

with Magnet 

MANUAL 

FAN 

AUTO 

LOW 

HIGH 

OFF 

Secure wires 

with wire tie

Secure blower 

with 3 bolts

C. Blower (Optional)

Door Handle

Spring 

Handle 

2 inch (51mm) clearance 

required from bend in door 

handle rod to end of spring 

handle.

Shock Risk

.

•  Do NOT remove grounding prong 

from plug.

•  Route cord away from appliance.

•  Do NOT route cord under or in front 

of appliance.

•  Plug directly into properly grounded 3 

prong receptacle.

CAUTION

Summary of Contents for 3100 Millennium

Page 1: ... glass and appliance will cause burns Do not touch glass until it is cooled Use leather gloves when reloading fuel NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flamma...

Page 2: ...liance Chimney 11 B Chimney Termination Requirements 12 C 2 10 3 Rule 12 D Chimney Height Rise and Run 13 E Venting Components 13 F Chimney Systems 13 G Installing Chimney Components 15 H Proper Draft 15 5 Appliance Set Up 16 A Outside Air Kit Installation 16 B Door Handle Assembly 17 C Blower Optional 17 6 Mobile Home Installation 18 7 Reference Materials 19 A Service Maintenance Log 19 B Accesso...

Page 3: ...sional lumber and data collected during EPA emission tests HHV includes the energy required to vaporize the water in the fuel A range of BTU outputs calculated using HHV Efficiency and the burn rates from the EPA tests using Douglas Fir dimensional lumber A peak BTU out of the appliance calculated using the maximum first hour burn rate from the High EPA Test and BTU content of seasoned cordwood 86...

Page 4: ...le and other interior components Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer WARNING This product and the fuels used to operate this product wood and the products of combustion of such fuels can expose you to chemicals including carbon blac...

Page 5: ...els of the house Causes include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water appliances and other combustion appliances Clothes dryers Location of return air vents to furnace or air conditioning Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks B Fire Safety To provide reasonable fire safety...

Page 6: ...l boards being careful not to damage product 2 Using 7 16 socket or wrench remove one bolt located inside front part of appliance Figure 6 1 3 Moving to the back of the appliance and using 7 16 socket or wrench remove two bolts Figure 6 1 4 Carefully pull appliance off of pallet and put in desired location following Hearth Pad and Clearance to Combustibles on pages 8 and 9 F Removal of Appliance f...

Page 7: ...ppliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installtion is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and corrective a...

Page 8: ... 4 in 501mm Figure 8 1 Front View Figure 8 3 Side View 25 1 2 in 648mm 29 1 2 in 749mm 15 1 8 in 383mm 21 in 533mm 11 in 278mm Figure 8 2 Top View 3 1 2 in 89mm 6 3 4 in 171mm 12 3 4 in 323mm 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Page 9: ...ons with single wall pipe Corner hearth pad dimensions with double wall pipe USA minimum flat wall hearth pad dimensions Canada flat wall hearth pad dimensions with double wall horizontal venting this dimension will vary depending installation 16 in from fuel door opening 16 in from fuel door opening Fuel loading door 31 5 8 in minimum 31 5 8 in minimum 39 in minimum 8 in 8 in 8 in 8 in 15 5 8 in ...

Page 10: ... diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum depth of Alcove shall be no more than 48 inches 1219mm and the referenced alcove clearances Canada must comply with CAN ULC S269 M87 for the 650 factory built chimney Table 10 1 NOTE Clearances may only be reduced by means approved by the regulatory authority havi...

Page 11: ...m space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven roof lines an...

Page 12: ...here are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61cm above any portion o...

Page 13: ...C S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the appliance The furthe...

Page 14: ...mended by chimney connector manufacturer Figure 14 2 Instructions 1 Open inside wall at proper height for the chimney connector to entry the masonry chimney Figure 14 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame from 2 x 2 framing lu...

Page 15: ...e connection at the flue collar should be secured with 3 sheet metal screws Make sure to follow the minimum clearances to combustibles Where passage through the wall or partition of combustible construction is desired in Canada the installation shall conform to CAN CSA B365 Factory built listed chimney connector vented A listed connector vented must be used when installing this appliance in a mobi...

Page 16: ...he flex pipe as show in Figure 16 1 If that is the case you will need to order SRV7033 041 which includes a cover plate and sealing rope as shown in Figure 16 2 The goal is to seal the pedestal so no room air can leak into the pedestal or for cold air infiltration A Outside Air Kit Installation A source of air oxygen is necessary in order for combustion to take place Whatever combustion air is con...

Page 17: ...aining the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 17 2 MANUAL Over rides the Snap Disc AUTO Fan will turn ON OFF Automatically by the Snap Disc Controls the Fan Speed Snap Disc Bracket with Magnet MANUAL FAN AUTO LOW HIGH OFF Secure wires with wire tie Secure blower with 3 bolts C Blower Opti...

Page 18: ...n where the chimney or other component penetrates to the exterior of the structure You must use a Quadra Fire Outside Air Kit Part OAK ACC and depending on floor installation Part SRV7033 041 for installation in a mobile home Asphyxiation Risk NEVER INSTALL IN A SLEEPING ROOM Consumes oxygen in the room WARNING CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE...

Page 19: ...19 September 9 2019 7033 350E 31M ACC C 7 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service ...

Page 20: ...20 September 9 2019 7033 350E 31M ACC C Date of Service Performed By Description of Service ...

Page 21: ... 1 Pkg of 10 25221A 10 Y Button Head 1 4 20 x 5 Pkg of 20 32328 20 Y Nut Keps Lock 10 32 Pkg of 40 226 0050 40 Y Nut Keps Lock 8 32 Pkg of 40 226 0060 40 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Screw Sheet Metal 8 x 1 2 S Grip Pkg of 40 12460 40 Y Washer 1 4 Sae Pkg of 24 28758 24 Y ITEM DESCRIPTION COMMENTS PART NUMBER ACCESSORIES Blower Assembly BK ACC Blower Convection Replacement...

Page 22: ...g and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 Not...

Reviews: