3
September 9, 2019
7033-350E
31M-ACC-C
Model:
3100 Millennium Wood Appliance
Laboratory:
OMNI Test Laboratories, Inc.
Report No:
0061WS066S
Type:
Listed Room Appliance, Solid
Fuel Type
Standard:
UL1482-11 (R2015) and ULC
S627-00 and (UM) 84-HUD, Mobile
Home Approved.
EPA Certification
Number:
86-17
EPA Certified Emissions:
1.9 grams per hour
*LHV Tested Efficiency:
78.3%
**HHV Tested Efficiency:
72.5%
***EPA BTU Output:
13,900 to 29,100 / hr
****Peak BTU/Hour
Output:
51,000
Vent Size:
6 inches
Firebox Size:
2 cubic feet
Recommended Log
Length:
16 inches
Fuel
Seasoned Cord Wood
(20% moisture)
*Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. LHV assumes the moisture
is already in a vapor state so there is no loss in energy
to vaporize.
**Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. HHV includes the energy
required to vaporize the water in the fuel.
***A range of BTU outputs calculated using HHV
Efficiency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
****A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efficiency.
This wood appliance needs periodic inspection and repair for proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
1
Important Safety Information
A. Appliance Certification
B. BTU & Efficiency Specifications
NOTE:
This installation must conform with local codes. In the absence of local codes you must comply with (UM) 84-
HUD and NFPA211 in the U.S.A. and CAN/CSA-B365 Installation Codes in Canada.
This 3100 Millennium is
Certified to comply with
2020 crib wood particulate
emission standards.