background image

7

02/23

7039-802G

This wood appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate 

this wood appliance in a manner inconsistent with operating instructions in this manual.

A. Appliance Safety Certification

C. BTU & Efficiency Specifications

NOTE:

 This installation must conform with local codes. In the absence of local codes you must comply with 

(UM) 84-

HUD and NFPA211 in the U.S.A. and CAN/CSA-B365 Installation Codes in Canada. 

Listing and Code Approvals

Model Number:

21M-ACC-C

Laboratory:

OMNI Test Laboratories, Inc.

Report Number:

0061WS070S

Type:

Listed Room Appliance, Solid 

Fuel Type

Standard:

UL1482, ULC S627-00 and (UM) 

84-HUD. Mobile Home Approved.

The 21M-ACC-C is Certified 

to comply with 2020 crib wood 

particulate emission standards.

EPA Certification #:

Number: N/A

EPA Certified Emissions:

1.7 grams per hour

*LHV Tested Efficiency:

82.3%

**HHV Tested Efficiency:

76.1%

***EPA BTU Output:

13,700 to 29,500 / hr.

****Peak BTU/Hour 

Output:

44,400

Vent Size:

6 inches

Firebox Size:

1.48 cubic feet

Recommended Log 

Length:

16 inches

Fuel

Seasoned Cord Wood 

(20% moisture)

* Weighted average LHV (Low Heating Value) efficiency 

using Douglas Fir dimensional lumber and data collected 

during EPA emission tests in accordance with the 

requirements of CSA B415.1. LHV assumes the moisture 

is already in a vapor state so there is no loss in energy to 

vaporize.

** Weighted average HHV (High Heating Value) efficiency 

using Douglas Fir dimensional lumber and data collected 

during EPA emission tests in accordance with the 

requirements of CSA B415.1. HHV includes the energy 

required to vaporize the water in the fuel.

*** A range of BTU outputs calculated using HHV 

Efficiency and the burn rates from the EPA tests, using 

Douglas Fir dimensional lumber.
**** A peak BTU out of the appliance calculated using 

the maximum first hour burn rate from the High EPA Test 

and BTU content of seasoned cordwood (8600) times 

the efficiency.

B. Appliance Emissions Certification

Model Number:

21M-ACC-C

Laboratory:

PFS-TECO

Report Number:

19-530

Standard:

Method 28 and 5G, and 

ASTM E2515

Can be found at:

www.quadrafire.com/about-us/epa-certification

Summary of Contents for 21M-ACC-C

Page 1: ...MATIC COMBUSTION CONTROL ACC MODEL NUMBER 21M ACC C If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store o...

Page 2: ...8 in USA Fuel loading door 5 3 4 in 2 1 4 in 29 5 8 in minimum 39 in minimum CANADA 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1245mm 49 in minimum 1006mm 39 5 8 in minimum Made in U S A of US and...

Page 3: ...7 B Appliance Emissions Certification 7 C BTU Efficiency Specifications 7 D Glass Specifications 8 E Mobile Home Approved 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions A Over Fir...

Page 4: ...on boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baffles 6 years 3 years X...

Page 5: ...overed by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRANTY...

Page 6: ...INDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The appliance...

Page 7: ...r Output 44 400 Vent Size 6 inches Firebox Size 1 48 cubic feet Recommended Log Length 16 inches Fuel Seasoned Cord Wood 20 moisture Weighted average LHV Low Heating Value efficiency using Douglas Fir...

Page 8: ...maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diam...

Page 9: ...ver such as in a shed or covered with a tarp plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In rece...

Page 10: ...n the stove top after start up you know the stove is hot enough and it may be time to adjust the air control if a sufficient ember bed has also been established Note that the stove will warm up much s...

Page 11: ...Combustion Control system an over fire situation can occur and may result in a chimney fire Over firing will void the appliance warranty WARNING Injury Risk Gloves recommended CAUTION Figure 11 2 HIG...

Page 12: ...are in the immediate area of the appliance Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the appliance NEVER light or rekindle fire with kerosene gasoline or...

Page 13: ...turning the speed control clockwise to Low or counterclockwise to High 3 Snap Disc Location If you find the blower coming on and off at undesirable temperatures relocate the snap disc to another locat...

Page 14: ...rnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should...

Page 15: ...he speed is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer Table 15 1 Fire Risk DO NOT BURN GARBAGE OR FLAMM...

Page 16: ...r 4 cords of wood The chimney and chimney cap must be inspected for soot and creosote every two months during the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m measur...

Page 17: ...nnector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be removed t...

Page 18: ...lass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause the g...

Page 19: ...with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket WARNING Fire Risk Firebox damage due to improper baffle placeme...

Page 20: ...ge 13 of the Installation manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Selection Storage on page 9 Bed of coals not e...

Page 21: ...r will permanently stain glass on next firing Refer to maintenance instructions NOTE Replace with 5mm ceramic glass only Service Part SRV7000 013 1 Ensure that the fire is out and the appliance is coo...

Page 22: ...SRV230 0470 1 Locate the snap disc bracket assembly at the bottom left rear corner of the appliance 2 A magnet holds the bracket to the appliance Pull the bracket down away from the appliance to expos...

Page 23: ...eramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 23 3 and Figure 23 4 5 To re instal...

Page 24: ...r to replace the tube channel assembly a clearance of 19 inches 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available the...

Page 25: ...25 02 23 7039 802G 6 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Page 26: ...26 02 23 7039 802G Date of Service Performed By Description of Service...

Page 27: ...ervice Parts 21M ACC C Beginning Manufacturing Date Feb 2020 Ending Manufacturing Date Active R Part number list on following pages 2100 Millennium Wood Stove Advanced Combustion Control ACC 01 23 1 2...

Page 28: ...832 0550 Pkg of 6 832 3040 4 2 Brick 5 3 4 x 4 1 2 x 1 1 4 Qty 3 Req SRV7128 039 4 3 Brick 8 x 4 1 2 x 1 1 4 Qty 2 Req SRV7128 022 4 4 Brick see diagram Qty 1 Req SRV7128 807 4 5 Brick see diagram Qt...

Page 29: ...in H SRV7000 013 Y Gasket Glass Tape Field cut to Size 5 Ft Length 832 0460 Y 10 4 Frame Glass GL FRM 21M 10 5 Screw Flat Head Philips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 11 Door Handle Assembly 832 05...

Page 30: ...SRV7039 002 17 Tube Channel Top Access Cover SRV7039 114 Component Pack SRV7039 057 18 1 Burn Rate Control Assembly SRV7039 016 18 2 Spring Handle 1 4 Black SRV7000 614 Y 18 3 Timer Air Control Assem...

Page 31: ...lower Control Box W Switch SRV7000 194 Y Blower Convection 812 4900 Y Component Pack 7033 051 Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 703...

Page 32: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Reviews: