19
02/23
7039-802G
INCORRECT POSITIONS
C. Correct Baffle & Blanket Placement
Ceramic Blanket and Baffle Board are NOT in contact
with the back of the firebox.
Ceramic Blanket is NOT in contact with the back of the
firebox and NOT even with the Baffle Board in the front.
Ceramic Blanket is bunched up at the back of the firebox
and NOT even with the Baffle Board in the front.
Ceramic Blanket
Back of
Firebox
Baffle Board
Figure 19.2
Figure 19.1
CORRECT POSITION
Ceramic Blanket and Baffle Board MUST be in contact
with the back of the firebox and even with each other in
the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Baffle Retainer
Bracket
WARNING
Fire Risk.
Firebox damage due to improper baffle
placement is not covered by warranty.
Operate the wood burning appliance with the
baffle in the correct position only.
Not doing so could result in:
•
Reduced efficiency
•
Overheating the chimney
•
Overheating the rear of the firebox
• Poor performance
Ensure correct baffle placement and replace
baffle components if damaged or missing.
The baffle boards are FRAGILE. Use extreme caution
when loading firewood to prevent:
•
Cracking, breaking or damaging the baffle boards
DO NOT operate the appliance without baffle boards
CAUTION