RSM-5c Meter Kits: kWh Meters 

3-Phase kWh Meter - Wye 

RSM5c 120100-3
RSM5c 120200-3
RSM5c 120400-3
RSM5c 120800-3
RSM5c 277100-3
RSM5c 277200-3
RSM5c 277400-3
RSM5c 277800-3

Catalog #

120/208V

277/480V

100
200
400
800
100
200
400
800

3 SPLIT CORE*

3 SPLIT CORE

3 SPLIT CORE*

3 SPLIT CORE

Figure 3-1








Volts

Amps

kWh Only

CTs included

Diagram

3-Phase kWh Meter – DELTA (“DTA”) 

RSM5c 480DTA100-2
RSM5c 480DTA200-2
RSM5c 480DTA400-2
RSM5c 480DTA800-2

Catalog #

480V

100
200
400
800

2 SPLIT CORE

Figure 3-2




Volts

Amps

kWh Only CTs included

Diagram

Kits include meterhead, fuse block, back box and required current transformers.
Enclosure: 6.9”H X 9.8”W X 4.9”D

A

B

C

N

C

A

B

For 1600 AMP or 3200 AMP, see page 28. 
*Kits with solid core current transformers are also available:

RSM5c 120100-3SL (includes 3 

SOLID

 CORE CTs) 

RSM5c 120200-3SL (includes 3 

SOLID

 CORE CTs) 

RSM5c 277100-3SL (includes 3 

SOLID

 CORE CTs) 

RSM5c 277200-3SL (includes 3 

SOLID

 CORE CTs)

25

Chapter 9

 

-Ordering Information -

RSM-5 Meter Kits: 

kWh for Large Service Meters 

3-Phase kWh Meter - Wye

RSM5 1201600-3
RSM5 1203200-3
RSM5 2771600-3
RSM5 2773200-3

Catalog #

120/208V

277/480V

1600
3200
1600
3200

3 SPLIT CORE

Figure 3-4




Volts

Amps kWh Only

CTs included

Diagram

Single-Phase kWh Meter – Wye 

RSM5c 120100-2SL
RSM5c 120200-2SL
RSM5c 277100-2SL
RSM5c 277200-2SL

Catalog #

100
200
100
200

2 SOLID CORE

Figure 3-3




Volts

Amps kWh Only CTs included

Diagram

For 1600Amp & 3200Amp Only
Kits include meterhead, fuse block, back box and required current transformers.
Enclosure:  13.5”H X 8.5”W X 4.5W

RSM–5c Meter Kits: kWh Meters

Kits include meterhead, fuse block, back box and required current transformers.
Enclosure: 6.9”H X 9.8”W X 4.9”D

A

B

C

N

120V/208V

or

120/240V

277/480V

Chapter 9

 

-Ordering Information -

26

All meters have built-in Power Line Communications capability.

All meters have built-in Power Line Communications capability.

Summary of Contents for RSM-5c

Page 1: ...Table of Contents Manual 3 Phase kWh 3 Phase Demand Single Phase kWh...

Page 2: ...RSM 5c RSM 5 Installation Manual Power Line Communications Metering Systems...

Page 3: ...6 Chapter 4 Menu Navigation 11 Chapter 5 Verifying Meter Functionality 15 Chapter 6 Resetting Demand Values For D Models 18 Chapter 7 Reading the Display 19 Chapter 8 Metering Specifications 21 Chapte...

Page 4: ...raining and are qualified to work with electricity and electrical metering equipment All applicable national and local electrical codes and standards must be followed Failure to follow proper procedur...

Page 5: ...abnormally proceed with caution The safety of the device may be impaired Do not install the meter in the presence of explosive or combustible gas or gas vapor Do not install the meter on an electrical...

Page 6: ...on with a 12 AWG stranded wire with white insulation These voltage connections can be made in any way that meets local codes and requirements A service disconnect switch for the hot wires is required...

Page 7: ...nd 4 above for each CT until all CTs have been installed and connected to the MCI screw terminals Chapter 2 RSM 5c and RSM 5 Installation 5 The following diagrams show the necessary fuse block connect...

Page 8: ...nnections Figure 3 3 1 Phase 3 Wire 120 240V 120 208V or 277 480V Network Fuse Block Connections Chapter 3 Fuse Block Connections 8 Figure 3 4 RSM 5 3 Phase 4 Wire Wye with High Current Adapter HCA 16...

Page 9: ...ogic com COPYRIGHT 2008 www quadlogic com Figure 3 6 RSM 5 3 Phase 4 Wire Wye with High Current Adapter HCA All CTs must be the same primary amperage and secondary amperage must be 5 Amp 9 10 Chapter...

Page 10: ...hown in figure 4 3 Each main menu heading will be displayed in two second intervals Note that the RSM 5c and RSM 5 default to the kWh register Figure 4 2 Meter LCD Main Menu headings Chapter 4 Menu Na...

Page 11: ...COPYRIGHT 2008 www quadlogic com COPYRIGHT 2008 www quadlogic com Chapter 4 Menu Navigation Figure 4 4 Display Menu Structure For an RSM 5c and RSM 5 Meter 13 Chapter 4 Menu Navigation 14...

Page 12: ...Display Scroll button Scroll down by pressing and releasing the Display Scroll button until the following screen is displayed The A mperage reading is the indication of current The A mperage reading...

Page 13: ...as above 17 Resetting Demand Values For D Models Chapter 6 BE CERTAIN TO RECORD THE CURRENT PEAK DEMAND WITH THE TIME AND DATE BEFORE RESETTING THE DEMAND Once the user resets the demand according to...

Page 14: ...ge How CT multipliers are calculated 0 1 Amp CTs The multiplier values for CTs with 0 1A secondary ratings are derived by dividing the primary side rating by 100 For example a 50 0 1A rated CT will ha...

Page 15: ...r off 500msec Max Pulse Rate Power on 10pulses sec max Power off 1 pulse sec max 21 Chapter 8 Metering Specifications When RSM 5 loses power the pulse accumulator still has the capability to record pu...

Page 16: ...for the RSM 5c and RSM 5 products and include the complete meter assembly meterhead fuse block and back box as well as the required current transformers CTs for operation Meters CTs not included page...

Page 17: ...s RSM5c 120200 3SL includes 3 SOLID CORE CTs RSM5c 277100 3SL includes 3 SOLID CORE CTs RSM5c 277200 3SL includes 3 SOLID CORE CTs 25 Chapter 9 Ordering Information RSM 5 Meter Kits kWh for Large Serv...

Page 18: ...alog 120 208V 277 480V 1600 3200 1600 3200 3 SPLIT CORE Figure 3 4 Volts Amps kWh and Demand CTs included Diagram 3 Phase Demand Meter Delta DTA RSM5 480DTA1600 2D RSM5 480DTA3200 2D Catalog 1600 3200...

Page 19: ...mand kWh Demand 4 Pulse Inputs Diagram 3 Phase Meter DELTA DTA A B C N Single Phase kWh Meter Wye RSM5c 120 2PH RSM5c 277 2PH Catalog 120 208V 277 480V 0 1A Figure 3 3 Volts Amps kWh Only Diagram C A...

Page 20: ...ts Diagram 3 Phase Meter DELTA DTA 0 1Amp A B C N C A B Dimension 13 5 X 8 5 X 4 5 RSM5 480DTA01A D RSM5 480DTA01AMD RSM5 480DTA01ARSD RSM5 480DTA01A PD Catalog 480V 0 1A Figure 3 2 Volts Amps kWh Dem...

Page 21: ...and 4 Pulse Inputs Diagram 3 Phase Meter DELTA DTA CL10 accepts one or two sets of 5Amp CTs A B C N B C A RSM5 480DTACL10 D RSM5 480DTACL10MD RSM5 480DTACL10RSD RSM5 480DTACL10 PD Catalog 480V 10A Fig...

Page 22: ...Added clarifying note Correction of memory size to 512 kilobyte Meets ANSI C12 1 Correction of voltage to 480V Delta Qualified fuse type Use shielded twisted pair for 50 CT extensions Deleted amperage...

Page 23: ......

Page 24: ...QUADLOGIC 33 00 Northern Blvd Long Island City NY 11101 Tel 212 930 9300 Fax 212 930 9394 www quadlogic com RSM5 5c MANR2 0 R...

Page 25: ...3 Phase kWh...

Page 26: ......

Page 27: ......

Page 28: ...3 Phase Demand...

Page 29: ......

Page 30: ......

Page 31: ...Single Phase kWh...

Page 32: ......

Page 33: ......

Reviews: