Functions - Persistent Between Modes
11. Audio Input Left
Audio input for Data Bender’s left channel. The left input normals to both channels when no cable
is present in Audio input Right.
Input Range: 10Vpp AC-Coupled (input level configurable via Shift+Mix function)
12. Audio Input Right
Audio input for Data Bender’s right channel.
Input Range: 10Vpp AC-Coupled (input level configurable via Shift+Mix function)
13. Audio Output Left
Audio output for Data Bender’s left channel.
Input Range: 10Vpp
14. Audio Output Right
Audio output for Data Bender’s right channel.
Input Range: 10Vpp
17
Calibration
If your Data Bender was purchased new is on the most recent firmware from the factory, then your
module has already been precisely calibrated to track 1V/Oct on Bend in Micro Mode. If you are
either:
• Unsure if your Data Bender is calibrated due to it being used.
• Updating your Data Bender to the most recent firmware.
• Looking to recalibrate your Data Bender
Then you can follow the steps below to calibrate your module.
1. Hold down Mode, and boot up Data Bender. Hold the button down until the Bend LED is red
and the Break LED is white.
2. With no other CV/Gate inputs present in the module, patch in 1V (1 octave up from root on
your sequencer) to the Bend CV input.
3. Press Bend. The LED above Bend will now illuminate Gold.
4. Patch 3V (3 octaves up from root on your sequencer) into the Bend CV input.
5. Press Bend. The LED above Bend will now illuminate Green.
6. To save and exit calibration mode, press Shift. Your Data Bender is now calibrate and in nor-
mal operating mode.
7. To restore the factory calibration, press the Break button at any point during the calibration
mode, then press Shift to save and exit calibration.