Functions - Persistent Between Modes
Shift+Clock Button: Gate Behaviors
While holding shift, the Clock LED will indicate whether the gates are configured as momentary or
latching.
Pressing the button while holding shift will toggle between the two options:
• When the LED is blue the gates are
latching
(each trigger input will toggle the state of the gat-
ed controls).
• When the LED is green the gates are
momentary
(an incoming gate signal will hold the state of
the button on if it is off, as long as it is held high).
Latching Gates
Momentary Gates
Shift+Mode Button: Corrupt Offerings
Holding Shift and pressing Mode will swap between the current Data Bender Corrupt effect offer-
ings and the original offerings.
• When the Mode LED is blue, all 5 effects on Corrupt are available.
• When the Mode LED is green, only the original 3 effects on Corrupt are available, Decimate,
Dropout, and Destroy.
ON
OFF
ON
OFF
Storing Settings Between Power Cycles
Several Settings are stored between power cycles. Settings are stored whenever the Shift button is
released, as frequently as once every two seconds.
The following settings are stored:
• Bend state
• Break state
• Corrupt Mode
• Clock source
• Processor Mode (Micro, Macro)
• Stereo Mode (Unique, Shared)
• Windowing amount
• Latching/Momentary gate behavior
• Latching/Momentary freeze button behavior
• Corrupt as Reset behavior
16