Display
Function
HEAt
Unit is warming up no function available
A001-A512 DMX address
FS-1 to 5
Manual Fan Speed 1=slow, 5=high
HO-0 to 5
Manual Haze output 0 = off, 1 = low, 5 = high
FS (Fan Speed) and HO (Haze Output) are settings for continuous stand-alone operation and
will override any remote control of the HZ-3
DMX MODE
When in DMX mode there are two channels with the following functions:
DMX
channel
DMX Scale
Detail function
CH 1
000 - 255
0% - 100% Fan Speed
CH 2
000 - 255
0% - 100% Haze Output
TIMER CONTROLLER
The timer controller can be used to control the HZ-3 remotely.
Please note Fan Speed (FS) and Haze Output (HO) must be set to zero for the remote timer
controller to operate.
1.
Timer on/off button
2.
Continuous output
3.
Manual override button
4.
Timer LED indicator (Illuminated Yellow when timer
active)
5.
Manual ready indicator (Illuminates Green when ready)
6.
Power indicator (Illuminates red when power is on)
7.
Adjust the amount of Haze released (between 0
–
100%)
NOTE
:
The below controls are only used when in timer mode
8.
Adjust the interval gap between each release of Haze
(between 0
–
30 Min approximately)