User manual – ATLANTIS
151.554UK
6
13. Master / Slave mode:
Set DIP switch 10 & 9 to ON. The master unit will control now all the slave units. Select on the master
device the program mode Automatic / Sound active mode this device then works as master device and
controls all other slave devices (switch 1 on) which are to be connected to the master device via a 2 core
screened cable. Connect the out XLR connector with the IN connector of the next device.
14. DMX Controlling :
DMX channel
DMX scale
Detail function
000 - 199
Speed control quick to slow
200 - 249
Auto running mode
CH 1
250 - 255
Sound control mode
000 – 031, 128 - 131
Not working
032 - 063
Mode 1
064 - 095
Mode 2
096 - 123
Mode 3
CH2-8
7clusters
working
separately
132 - 255
Static display
000 - 010
CH2-8 allow
(more than 10 not allowed)
011 – 031, 128 - 131
Not working
032 - 063
Mode 1
064 - 095
Mode 2
096 - 123
Mode 3
CH 9
All 7 clusters could be
controlled
132 - 255
Static display
Set DIP switch 10 to OFF position and control the DMX receiving address with dip switches 1-9 and you’re all
set-up to start the DMX receiving mode.
(Note: 1 = On, 0 = Off)
DIP Switches
DMX Address
9
8
7
6
5
4
3
2
1
01
0
0
0
0
0
0
0
0
1
02
0
0
0
0
0
0
0
1
0
03
0
0
0
0
0
0
0
1
1
04
0
0
0
0
0
1
1
0
0
…
..
..
..
..
..
..
..
..
..
509
1
1
1
1
1
1
1
0
1