background image

User Manual 

 

 

 

151.269 / 151.272 

 

 

PART II Installation and Operation (continued) 

C. Select auto programs 

To  select  auto  programs,  turn  the  dipswitch  #1  of  the  2

nd

  group  dipswitches  off  and 

dipswitch# 8 off. Auto programs are then selected by the various combining of dipswitches 
#2, #3 and #4 of group one dipswitches: 

DIP2  DIP3  DIP4 

Programs 

OFF  OFF 

OFF 

Program 1, red fading 

ON 

OFF 

OFF 

Program 2, green fading 

OFF  ON 

OFF 

Program 3, blue fading 

ON 

ON 

OFF 

Program 4, changing between red and green 

OFF  OFF 

ON 

Program 5, changing between red and blue 

ON 

OFF 

ON 

Program 6, changing between green and blue 

OFF  ON 

ON 

Program 7, fading among red, green and blue 

ON 

ON 

ON 

Program 8, changing among red, red and blue, blue 

 

The parameter, fading is specified by the various combining of dipswitch #5, #6 and #7 of 
group two dipswitches: 
 

DIP5  DIP6  DIP7 

FADING 

OFF  OFF 

OFF 

0%   

ON 

OFF 

OFF 

14.2% 

OFF  ON 

OFF 

28.4% 

ON 

ON 

OFF 

42.6% 

OFF  OFF 

ON 

56.8% 

ON 

OFF 

ON 

71% 

OFF  ON 

ON 

85.2% 

ON 

ON 

ON 

100% 

The  running  speed  of  auto  programs  is  adjusted  by  turning  the  knob  VR  located  at  the 
front panel of the fixture.

 

 

 
 

D. Sound Active mode 

Turn the dipswitch #1 off and #8 of group 2 dipswitches on, the fixture will be working   
in sound active mode with its sound sensitivity adjustable through knob VR.   
The path of the program is the same as Auto Program Mode, except that it is triggered   
by sound. 
 
 
 
 
 
 
 

 
 

Summary of Contents for 151.269

Page 1: ...USER MANUAL HIGH POWER LED DMX PAR64 CANS 151 269 151 272...

Page 2: ...power supply is off before installing wiring or servicing this product Danger This Product must be installed by a qualified electrician in accordance with NEC and relevant local codes Warning Do not...

Page 3: ...or further instructions Included Items 1 Ea 151 269 151 272 1 Ea User Manual 1 4 Specifications Qty of LEDs 36 PCS R 1W 12PCS G 1W 12PCS B 1W 12PCS Power Supply 110 240Vac Power Consumption 45W Dimens...

Page 4: ...User Manual 151 269 151 272 4 Part II Installation and Operation 2 1 Fixture Layout Operating Panel...

Page 5: ...s Wire Pin Marking Screw color Brown Live L Yellow or brass Blue Neutral N Silver Yellow or green Ground E Green 2 3 Understanding DMX A About DMX DMX is the abbreviation of Digital Multiplex It s uni...

Page 6: ...information 2 4 Operation Instructions The fixture employs two groups of dipswitches to access its functions Normally the dipswitches from 1st to 9th are used for encoding DMX address In addition the...

Page 7: ...0 0 Auto Program 2 0 1 0 0 0 Auto Program 3 0 0 1 0 0 Auto Program 4 0 1 1 0 0 Auto Program 5 0 0 0 1 0 Auto Program 6 0 1 0 1 0 Auto Program 7 0 0 1 1 0 Auto Program Auto Program 8 0 1 1 1 0 Sound Pr...

Page 8: ...termined by channel 4 Channel Value Function CH1 CH2 CH3 CH5 000 028 RGB Control Mode Red 000 255 Green 000 255 Blue 000 255 No Function 000 255 029 056 Program 1 057 084 Program 2 085 112 Program 3 1...

Page 9: ...ween green and blue OFF ON ON Program 7 fading among red green and blue ON ON ON Program 8 changing among red red and blue blue The parameter fading is specified by the various combining of dipswitch...

Page 10: ...ensure its long lifespan and bright light output While performing the cleaning please always make sure that the power cord is disconnected from the mains and use a moist lint free cloth Avoid using an...

Page 11: ...put of the first fixture and the output of the controller to be connected Wrong DMX address Check and unify the address setting Note when linked to the DMX controller no fixtures are set as master The...

Page 12: ...396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 27...

Reviews: