background image

User Manual 

 

 

 

151.269 / 151.272 

 

 

11 

 

3.3 Troubleshooting 

Trouble

 

Cause

 

Remedy

 

No power supply

 

Check the mains power switch and the cables.

 

  Fixtures do not 

responds.

 

Fuse burned

 

Disconnect the power and replace the fuse with 

the same specification. If the fuse is burned 

again, the problem should be cause by the 

circuit. Please consult the local service agency.

 

data errors

 

Check the data bus. Ensure the signal input   
of the first fixture and the output of the controller 
to be connected.

 

Wrong DMX address

 

Check and unify the address setting. 
Note: when linked to the DMX controller,   
no fixtures are set as master.

 

The reset is normal. 

But the fixtures do   

not responds or act 

abnormally via 

controller or   

Master /Slave.

 

The signal port of   
one lamp has failures.

 

Pull out the signal output and input of   
one fixture. Then connect both directly.   
If it works well, this fixture is proved to be   
the failed one. Handle the rest fixtures alike   
to check which fixture has problems.   
If any problem, please consult the local   
service agency. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

Summary of Contents for 151.269

Page 1: ...USER MANUAL HIGH POWER LED DMX PAR64 CANS 151 269 151 272...

Page 2: ...power supply is off before installing wiring or servicing this product Danger This Product must be installed by a qualified electrician in accordance with NEC and relevant local codes Warning Do not...

Page 3: ...or further instructions Included Items 1 Ea 151 269 151 272 1 Ea User Manual 1 4 Specifications Qty of LEDs 36 PCS R 1W 12PCS G 1W 12PCS B 1W 12PCS Power Supply 110 240Vac Power Consumption 45W Dimens...

Page 4: ...User Manual 151 269 151 272 4 Part II Installation and Operation 2 1 Fixture Layout Operating Panel...

Page 5: ...s Wire Pin Marking Screw color Brown Live L Yellow or brass Blue Neutral N Silver Yellow or green Ground E Green 2 3 Understanding DMX A About DMX DMX is the abbreviation of Digital Multiplex It s uni...

Page 6: ...information 2 4 Operation Instructions The fixture employs two groups of dipswitches to access its functions Normally the dipswitches from 1st to 9th are used for encoding DMX address In addition the...

Page 7: ...0 0 Auto Program 2 0 1 0 0 0 Auto Program 3 0 0 1 0 0 Auto Program 4 0 1 1 0 0 Auto Program 5 0 0 0 1 0 Auto Program 6 0 1 0 1 0 Auto Program 7 0 0 1 1 0 Auto Program Auto Program 8 0 1 1 1 0 Sound Pr...

Page 8: ...termined by channel 4 Channel Value Function CH1 CH2 CH3 CH5 000 028 RGB Control Mode Red 000 255 Green 000 255 Blue 000 255 No Function 000 255 029 056 Program 1 057 084 Program 2 085 112 Program 3 1...

Page 9: ...ween green and blue OFF ON ON Program 7 fading among red green and blue ON ON ON Program 8 changing among red red and blue blue The parameter fading is specified by the various combining of dipswitch...

Page 10: ...ensure its long lifespan and bright light output While performing the cleaning please always make sure that the power cord is disconnected from the mains and use a moist lint free cloth Avoid using an...

Page 11: ...put of the first fixture and the output of the controller to be connected Wrong DMX address Check and unify the address setting Note when linked to the DMX controller no fixtures are set as master The...

Page 12: ...396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 27...