ASSEMBLY

 

1

 

Attach the hose to the pump and tighten with a wrench.

 

2

 

Attach the hose to the gun and tighten with a wrench.

 

 

OPERATION

 

1

 

New sprayer / before you start

 

 

Your sprayer was factory tested in an oil solution which was left in the pump. 

 

Before using oil

-

base paint, flush with pump conditioner only. Before using 

 

water

-

base paint flush with pump conditioner, followed by soapy water, then 

 

a clean water flush.

 

2

 

Changing colours

 

 

Flush with a compatible solvent such as pump conditioner or water.

 

3

 

Changing from water

-

base to oil

-

base paint

 

 

Flush with soapy water, and then pump conditioner.

 

14

 

QTech 

QT290 Airless Sprayer

 

FLUSHING

 

WHEN TO FLUSH

 

1

 

Cleanup 

(for further detail turn to page 20).

 

2

 

Changing from oil

-

base to water base paint. 

Flush with pump conditioner, 

 

followed by soapy water, then a clean water flush.

 

3

 

Storage.

 

Always relieve pressure (see 

PRESSURE RELIEF PROCEDURE 

 

 

page 8) prior to storage or when machine is unattended.

 

 

Oil

-

base paint: 

Flush with pump conditioner. Ensure that there is no pressure 

 

in the unit, then close the priming valve.

 

 

Water

-

base paint: 

Flush with water, and then pump conditioner. 

 

 

For longer term storage fill with pump conditioner. 

 

 

Always ensure that there is no pressure in the unit, and close the prime/

 

pressure relief valve for storage.

 

4

 

Start

-

up after storage

Before using water

-

base paint, flush with soapy water 

 

and then with clean water. When using oil

-

base paint, flush out the pump 

 

 

conditioner with the material to be sprayed.

 

HOW TO FLUSH

 

1

 

Be sure the gun safety latch is engaged and there is no spray tip in the gun.

 

2

 

Pour enough clean, compatible solvent into a large, empty metal pail to fill 

 

 

the pump and hoses.

 

3

 

Place the suction tube into the pail.

 

4

 

Turn the Priming Valve to the 

Open

’, 

priming position.

 

5

 

Point the gun into the metal pail and hold a metal part of the gun 

 

 

firmly against the pail. 

To reduce the risk of static sparking which can cause 

 

fire or explosion, always hold a metal part of the gun firmly against the 

 

metal pail when flushing. This also reduces splashing. 

Disengage the gun 

 

safety latch 

 

and squeeze the gun trigger. Turn the ON/OFF Toggle Switch to 

 

the "ON" position and turn Pressure Control Knob clockwise to increase 

 

 

pressure just enough to start the pump.

 

6

 

Close the priming valve. This will allow solvent to be flushed through the 

 

pump, hoses and gun. Allow the unit to operate until clean solvent comes 

 

from the gun.

 

7

 

Release the trigger and engage the gun safety latch.

 

8

 

Whenever you shut off the sprayer, follow the 

PRESSURE RELIEF 

 

 

PROCEDURE.

 

15

 

Brought to you by 

Aristospray

 

Summary of Contents for QT290

Page 1: ...b Stephenstown Industrial Park Balbriggan County Dublin Ireland Australia 27 Tatura Avenue Gosford NSW 2250 Email sales aristospray com www Aristospray com www SprayForthedecorator com Phone UK 01895...

Page 2: ...im gun at scrap and pull trigger to clear Check tip for wear replace where necessary Check all filters are clear of debris clean or replace Ensure OK for coating tip combination change if necessary Ch...

Page 3: ...r 3000 psi SPECIFICATION Motor 1300 watt Weight 33 0 kg Warranty 2 years SUPPLIED COMPLETE WITH TriTech T360 airless spray gun TriTech Contractor 517 airless tip guard 1 4 x 15m textile braided hose a...

Page 4: ...k Grounded sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use...

Page 5: ...n to relieve residual fluid pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the open priming position to relieve residual fluid pressure 5 Re engage...

Page 6: ...NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator s manual to read ALWAYS wear a spray mask gloves and protective eye wear while spr...

Page 7: ...n result in serious bodily injury and property damage For detailed instructions on how to ground check your local electrical code ALWAYS ensure switch is in OFF position before plugging unit in Always...

Page 8: ...ure that there is no pressure in the unit and close the prime pressure relief valve for storage 4 Start up after storage Before using water base paint flush with soapy water and then with clean water...

Page 9: ...sure d Check the spray pattern The tip size and angle determines the pattern width and flow rate Spray a test pattern and then adjust the pressure to eliminate heavy edges Use a smaller tip size if th...

Page 10: ...lter use a brush dipped in an appropriate solvent Change or clean filters at least once a day Some types of latex may require a filter change after about four hours of operation SPRAY TIP SELECTION Sp...

Page 11: ...packings and reduce the packing life 20 QTech QT290 Airless Sprayer PACKINGS The packings are a wearing part If the pump can no longer maintain pressure has difficulty priming and paint seeps into th...

Page 12: ...8 12 290 010 PUMP HOUSING 1 09 12 003 OUTPUT NIPPLE PT 1 4 x 1 4 19PF 1 10 12 290 011 RETAINING NUT 1 11 12 002 COMPLETE PACKING KIT INC PARTS 05 06 11 14 16 19 20 1 12 12 008 PACKING SPACER 1 13 12 0...

Page 13: ...2 290 069 SOCKET CAP SCREW M5x55xP0 8 4 Brought to you by Aristospray 25 Control Box ITEM PRODUCT CODE DESCRIPTION QTY 70 1 12 290 091 1 ELECTRONICS UNIT 110V 1 70 2 12 290 091 2 ELECTRONICS UNIT 220V...

Page 14: ...UT NIPPLE PT 1 4 x 1 4 19PF 2 107 12 290 071 FILTER HOUSING 1 108 12 290 075 PRIMING VALVE 1 109 12 016 DRAIN TUBE PT1 8 x0 45M 1 110 12 290 078 SOCKET SET SCREW PT1 4 1 111 12 290 079 HEX NUT M5 P0 8...

Reviews: