TOXIC FLUID HAZARD

 

+  

 

ALWAYS 

remove tip guard & tip to clean 

AFTER 

pump is turned off and the 

 

pressure is relieved by following the 

PRESSURE RELIEF PROCEDURE

.

 

+  

 

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in 

 

eyes or on skin, inhaled or swallowed. Know the hazards of the fluid you are 

 

using. Store and dispose of hazardous fluid according to manufacturer, local, 

 

state and national guidelines.

 

+  

 

ALWAYS 

wear protective eyewear, gloves, clothing and respirator 

 

 

as recommended by fluid manufacturer.

 

 

HOSES

 

+  

 

Tighten all of the fluid connections securely before each use. High pressure 

 

fluid can dislodge a loose coupling or allow high pressure spray to be emitted 

 

from the coupling and result in an injection injury or serious bodily injury.

 

+  

 

Only use hoses with a spring guard. The spring guard helps protect the hose 

 

from kinks or other damage which could result in hose rupture and cause an 

 

injection injury. Do not allow kinking or crushing of hoses or allow it to vibrate 

 

against rough, sharp or hot surfaces.

 

+  

 

Use only conductive fluid hoses for airless applications. Be sure the gun is 

 

grounded through the hose connections. Use only high pressure airless hoses 

 

with static wire which are approved for 3000 psi.

 

+  

 

NEVER 

use a damaged hose, which can result in hose failure or rupture and 

 

cause an injection injury or other serious bodily injury or property damage. 

 

Before each use, check entire hose for cuts, leaks, abrasions, bulging of the 

 

cover, or damage or movement of couplings. If any of these conditions exist, 

 

replace the hose immediately.

 

+  

 

NEVER 

use tape or any device to try to mend the hose as it cannot contain 

 

the high pressure fluid. 

NEVER ATTEMPT TO RECOUPLE THE HOSE. 

 

 

It is not possible to recouple a high pressure hose .

 

12

 

QTech 

QT290 Airless Sprayer

 

GROUNDING

 

+  

 

Ground the sprayer and other components in the system to reduce the risk of 

 

static sparking, fire or explosion which can result in serious bodily injury and 

 

property damage. For detailed instructions on how to ground, check your 

 

 

local electrical code.

 

+  

 

ALWAYS 

ensure switch is in 

OFF 

position before plugging unit in.

 

Always ground all of these components:

 

1

 

Sprayer: 

plug the power supply cord, or extension cord, each equipped with 

 

an undamaged three

-

prong plug, into a properly grounded outlet. 

DO NOT 

 

USE AN ADAPTER. 

Use only a 3 wire extension cord that has a grounding 

 

plug, and a receptacle that will accept the grounding plug on the product. 

 

Make sure your extension cord is in good condition. When using an extension 

 

cord, be sure to use one heavy enough to carry the current your product will 

 

draw. If in doubt, use the next heavier gauge.

 

2

 

Fluid hose: 

use only grounded hoses.

 

3

 

Spray gun 

or dispensing valve: grounding is obtained through connection to 

 

a properly grounded fluid hose and pump.

 

4

 

All solvent pails must be conductive metal material and properly grounded. 

 

Do not place on a non conductive insulating surface unless a ground wire is 

 

added to a true earth such as a metal water pipe. ALWAYS 

ensure fire 

 

 

extinguishing equipment is readily available and properly maintained.

 

 

FLUSHING SAFETY

 

WHEN SPRAYING & CLEANING WITH FLAMMABLE PAINTS AND THINNERS

 

1

 

When spraying with flammable liquids, the unit must be located a minimum 

 

of 

 

25 feet away from the spraying area in a well ventilated area. Ventilation 

 

must 

 

be sufficient enough to prevent the accumulation of vapors.

 

2

 

To eliminate electrostatic discharge, ground the spray unit, paint bucket and 

 

spraying object. See 

GROUNDING

Use only high pressure airless hoses 

 

 

approved for 3000 psi which is conductive.

 

3

 

Remove the spray tip before flushing. Hold the metal part of the gun firmly to 

 

the side of a metal pail & use the lowest possible fluid pressure during flushing.

 

4

 

Never use high pressure in the cleaning process. 

USE MINIMUM PRESSURE

.

 

5

 

Do not smoke in spraying/cleaning area.

 

NEVER use cleaning solvents with flash points below 60°C/140°F. Some of these 
are: acetone, benzene, ether, gasoline, naphtha. Consult your supplier if in doubt.

 

13

 

Brought to you by 

Aristospray

 

Summary of Contents for QT290

Page 1: ...b Stephenstown Industrial Park Balbriggan County Dublin Ireland Australia 27 Tatura Avenue Gosford NSW 2250 Email sales aristospray com www Aristospray com www SprayForthedecorator com Phone UK 01895...

Page 2: ...im gun at scrap and pull trigger to clear Check tip for wear replace where necessary Check all filters are clear of debris clean or replace Ensure OK for coating tip combination change if necessary Ch...

Page 3: ...r 3000 psi SPECIFICATION Motor 1300 watt Weight 33 0 kg Warranty 2 years SUPPLIED COMPLETE WITH TriTech T360 airless spray gun TriTech Contractor 517 airless tip guard 1 4 x 15m textile braided hose a...

Page 4: ...k Grounded sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use...

Page 5: ...n to relieve residual fluid pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the open priming position to relieve residual fluid pressure 5 Re engage...

Page 6: ...NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator s manual to read ALWAYS wear a spray mask gloves and protective eye wear while spr...

Page 7: ...n result in serious bodily injury and property damage For detailed instructions on how to ground check your local electrical code ALWAYS ensure switch is in OFF position before plugging unit in Always...

Page 8: ...ure that there is no pressure in the unit and close the prime pressure relief valve for storage 4 Start up after storage Before using water base paint flush with soapy water and then with clean water...

Page 9: ...sure d Check the spray pattern The tip size and angle determines the pattern width and flow rate Spray a test pattern and then adjust the pressure to eliminate heavy edges Use a smaller tip size if th...

Page 10: ...lter use a brush dipped in an appropriate solvent Change or clean filters at least once a day Some types of latex may require a filter change after about four hours of operation SPRAY TIP SELECTION Sp...

Page 11: ...packings and reduce the packing life 20 QTech QT290 Airless Sprayer PACKINGS The packings are a wearing part If the pump can no longer maintain pressure has difficulty priming and paint seeps into th...

Page 12: ...8 12 290 010 PUMP HOUSING 1 09 12 003 OUTPUT NIPPLE PT 1 4 x 1 4 19PF 1 10 12 290 011 RETAINING NUT 1 11 12 002 COMPLETE PACKING KIT INC PARTS 05 06 11 14 16 19 20 1 12 12 008 PACKING SPACER 1 13 12 0...

Page 13: ...2 290 069 SOCKET CAP SCREW M5x55xP0 8 4 Brought to you by Aristospray 25 Control Box ITEM PRODUCT CODE DESCRIPTION QTY 70 1 12 290 091 1 ELECTRONICS UNIT 110V 1 70 2 12 290 091 2 ELECTRONICS UNIT 220V...

Page 14: ...UT NIPPLE PT 1 4 x 1 4 19PF 2 107 12 290 071 FILTER HOUSING 1 108 12 290 075 PRIMING VALVE 1 109 12 016 DRAIN TUBE PT1 8 x0 45M 1 110 12 290 078 SOCKET SET SCREW PT1 4 1 111 12 290 079 HEX NUT M5 P0 8...

Reviews: