QTech QT290 User Manual Download Page 2

CAUTION

 

This manual contains important warnings and information

 

PLEASE READ & KEEP FOR FUTURE REFERENCE

 

 

VERSION 

QT290

-

03

-

0619

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aristospray

 

2b Stephenstown Industrial Park, Balbriggan, County Dublin, Ireland

 

 

Declares that the

 

QTech QT290 Electric Airless Sprayer

 

is in compliance with the regulations included in:

 

 

2006/42/EC Machinery Directive

 

2014/35/EU Low Voltage Directive

 

2014/30/EU Electromagnetic Compatibility Directive

 

 

The standards applied by the manufacturer are:

 

 

EN55014

-

1:2006+A1; A1:2009+A2:2011

 

EN55014

-

1:2017

 

EN55014

-

2:2015

 

EN61000

-

3

-

2:2014

 

EN61000

-

3

-

3:2013

 

2

 

QTech 

QT290 Airless Sprayer

 

 

 

 

 

 

 

 

Brought to you by 

Aristospray

 

Check it

s on.

 

Turn 

pressure control knob 

clockwise to 

 

increase pressure

 

Check 

plug & cable 

for loose connections 

 

and/or damage

 

 

Check for 

error codes

, if any showing contact a

 

QTech dealer or technician for advice

 

 

Make sure it

s in the 

prime 

position

 

Open 

prime valve 

and purge air from pump

 

Ensure it

s not clogged, clean where necessary

 

Tighten if loose

 

Tap the 

suction tube 

connection a few times to 

 

loosen 

-

 if no result check that 

lower ball 

and/or 

 

seat 

is not worn or scarred

 

Change 

packings

; contact aQTech dealer or 

 

technician for advice

 

 

Check not empty

 

If clogged, reverse 

tip

, aim gun at scrap and 

 

pull trigger to clear

 

Check 

tip 

for wear, replace where necessary

 

Check all 

filters 

are clear of debris, clean 

 

or replace

 

Ensure OK for 

coating/tip 

combination, change 

 

if necessary

 

Check OK for spray, thin where appropriate

 

Check 

length & diameter 

compatible with 

 

pump & coating

 

Check not obstructed with debris, contact a

 

QTech dealer or technician for advice

 

 

Increase pressure

 

If clogged, reverse 

tip

, aim gun at scrap and 

 

pull trigger to clear

 

Check 

tip 

for wear, replace where necessary

 

Too thick   

Move gun faster, check far enough 

 

away from surface and tip size

 

Too thin   

Move gun slower, check close enough 

 

to surface and tip size

 

Check 

pressure control 

for wear, contact a

 

QTech dealer or technician for advice

 

3

 

Power switch
Pressure control knob

 

Supply plug & cable

 

 

Digital display

 

 

Prime valve

 

Air in paint

 

Suction filter 
Suction tube
Lower ball 

 

 

 

Pump leaking paint

 

 

 

Paint bucket

 

Spray tip

 

 

 

Filters 

 

 

Coating being sprayed

 

    

 

 

Hose

 

 

Prime valve

 

 

Pressure setting

 

Spray tip

 

 

 

Coating

 

 

 

 

Uneven spray

 

Motor won

t run

 

 

 

 

 

 

Pump does 

 

not cycle

 

 

Pump won

prime

 

 

 

 

 

 

 

 

 

Insufficient 
pressure at the 
gun or sudden 
loss of pressure

 

 

 

 

 

 

 

 

 

 

 

Bad quality 
spray pattern

 

SYMPTOM

 

CHECK OUT

 

PROCEDURE

 

Quick 

check

 

The information on this page is intended only as a quick guide. It is no way intended as 

 

a substitute to the information on the pages following, which the user should be fully 

 

acquainted with before using an electric airless sprayer.

 

Summary of Contents for QT290

Page 1: ...b Stephenstown Industrial Park Balbriggan County Dublin Ireland Australia 27 Tatura Avenue Gosford NSW 2250 Email sales aristospray com www Aristospray com www SprayForthedecorator com Phone UK 01895...

Page 2: ...im gun at scrap and pull trigger to clear Check tip for wear replace where necessary Check all filters are clear of debris clean or replace Ensure OK for coating tip combination change if necessary Ch...

Page 3: ...r 3000 psi SPECIFICATION Motor 1300 watt Weight 33 0 kg Warranty 2 years SUPPLIED COMPLETE WITH TriTech T360 airless spray gun TriTech Contractor 517 airless tip guard 1 4 x 15m textile braided hose a...

Page 4: ...k Grounded sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use...

Page 5: ...n to relieve residual fluid pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the open priming position to relieve residual fluid pressure 5 Re engage...

Page 6: ...NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator s manual to read ALWAYS wear a spray mask gloves and protective eye wear while spr...

Page 7: ...n result in serious bodily injury and property damage For detailed instructions on how to ground check your local electrical code ALWAYS ensure switch is in OFF position before plugging unit in Always...

Page 8: ...ure that there is no pressure in the unit and close the prime pressure relief valve for storage 4 Start up after storage Before using water base paint flush with soapy water and then with clean water...

Page 9: ...sure d Check the spray pattern The tip size and angle determines the pattern width and flow rate Spray a test pattern and then adjust the pressure to eliminate heavy edges Use a smaller tip size if th...

Page 10: ...lter use a brush dipped in an appropriate solvent Change or clean filters at least once a day Some types of latex may require a filter change after about four hours of operation SPRAY TIP SELECTION Sp...

Page 11: ...packings and reduce the packing life 20 QTech QT290 Airless Sprayer PACKINGS The packings are a wearing part If the pump can no longer maintain pressure has difficulty priming and paint seeps into th...

Page 12: ...8 12 290 010 PUMP HOUSING 1 09 12 003 OUTPUT NIPPLE PT 1 4 x 1 4 19PF 1 10 12 290 011 RETAINING NUT 1 11 12 002 COMPLETE PACKING KIT INC PARTS 05 06 11 14 16 19 20 1 12 12 008 PACKING SPACER 1 13 12 0...

Page 13: ...2 290 069 SOCKET CAP SCREW M5x55xP0 8 4 Brought to you by Aristospray 25 Control Box ITEM PRODUCT CODE DESCRIPTION QTY 70 1 12 290 091 1 ELECTRONICS UNIT 110V 1 70 2 12 290 091 2 ELECTRONICS UNIT 220V...

Page 14: ...UT NIPPLE PT 1 4 x 1 4 19PF 2 107 12 290 071 FILTER HOUSING 1 108 12 290 075 PRIMING VALVE 1 109 12 016 DRAIN TUBE PT1 8 x0 45M 1 110 12 290 078 SOCKET SET SCREW PT1 4 1 111 12 290 079 HEX NUT M5 P0 8...