QSW-6300 Series Switches Hardware Installation and Reference Guide
Product Overview
20
1.5.5. LED
LED
Panel
Identification
Status
Meaning
System status
LED
Status
Off
The switch is not powered on.
Blinking
green
(3 Hz)
Initialization is in progress.
Continuous blinking indicates a
fault.
Blinking
green (10 Hz)
It is used for on-site positioning of
the device, and allows operation
and maintenance personnel to
perform remote power on and off
control.
Solid green
The switch is operational.
Solid yellow
Temperature alarm:
1. The temperature of inlet/outlet
vent exceeds the warning
threshold.
2. The power is insufficient for
the system.
Check the working environment
of the switch and power supplies
immediately.
Solid red
The switch is faulty. For details,
see
Troubleshooting
.
Power supply
status LED
PWR1/PWR2
Off
The power supply module is not
in place or not powered on.
Solid green
The power supply module is in
place and operational.
Solid red
The redundant power is faulty or
the AC power cord is not
connected.
MGMT port
status LED
MGMT
Off
The port is not connected.
Solid green
The port is connected at 1000
Mbps.
Blinking
green
The port is receiving or
transmitting data at 1000 Mbps.
Solid yellow
The port is connected at 10/100
Mbps.