![QSI quantum Operation Manual Download Page 18](http://html1.mh-extra.com/html/qsi/quantum/quantum_operation-manual_3304930018.webp)
Steam Q1a Operation Manual Rev 4.1.2
18/24
24 August 2006
26
Dynamo
29 Boiler
Pop-off
30
Boiler Blow down
31 Water
Injector
34
Coupler Sounds
37
Air Brake Sounds
See your
Steam Model Specifications sheet for Individual Sound Volume default settings.
Bell Type Selection (CV 55.3.1)
Your Quantum System may have more than one type of Bell sound. To select different Bell sounds,
•
Set CV 49 to 3.
•
Set CV 50 to 1
•
Set CV 55 to a number from 0 to n to select Bell type. The default is 1; “Feedback Bell
41
” selection is 0 (used for locos where the
prototypes did not have bells).
Note: To determine the number of Bell types, n, set CV 49 to 3, set CV 50 to 0, and set CV 64 to 55 to hear verbal response in Ops Mode.
Note: If you set “n” at a higher value than the number of available Bells, Quantum will select the “Feedback Bell”, type “0”.
Standard Throttle Control and Regulated Throttle Control Options (CV 56.4)
•
Set CV 49 to 4.
•
Set CV 56 to 0 for Standard Throttle Control; 1 for Regulated Throttle Control. The default is 1.
Note: CV 2, CV 3, CV 4, CV 5 and speed tables apply to both Standard and Regulated Throttle Control.
Reset all
42
CV’s to Factory Default Values (CV 56.128.255)
Note: This does not affect Analog settings, except for volumes.
•
Set CV 49 to 128.
•
Set CV 50 to 255.
•
Set CV 56 to 113
43
. In Ops mode, you will hear “Reset” when reset is completed.
Special Procedure for Short or Extended Address Programming (CV 56.129)
If you cannot program your Short or Extended ID number in Service Mode and your DCC command station prevents you from setting either
of these addresses in Ops Mode (using CV 1, or CV 17 and CV 18) use the following alternative procedures to program your locomotive’s
ID’s.
Alternate Procedure for Entering Short (Primary) Address in CV 56.129.1 in Ops Mode
•
Set CV 49 to 129.
•
Set CV 50 to 1.
•
Set CV 56 to your Short Address (1 or 2 digits). Hear the address spoken back (“CV 1 = X”).
•
If necessary, set CV 29, bit 5 to ‘0’ (or set CV 29 to 6 which is factory default) to enable your new Primary Address.
Procedure for Entering Long (Extended) Address in CV 56.129.17 in Ops Mode
•
Determine the value of CV 17 and CV 18 for your Extended Address from the ID Table in your
Steam Model Specification Sheet or
follow instructions in CV 17 and CV 18 in the
Quantum DCC Reference Manual (Version 4) to calculate a different ID number.
•
Set CV 49 to 129.
•
Set CV 50 to 17.
•
Set CV 56 to the value of CV 17 from the table. Hear the value of CV 17 spoken out (“CV 56.129.17 = X”).
•
Set CV 50 to 18.
•
Set CV 56 to the value of CV 18 from the table. Hear the value of CV 18 spoken out (“CV 56.129.18 = X”).
44
41 Feedback Bells produce a single light “ding” when turning the bell on and a double “ding” when shutting the bell off. This bell type is suitable for locos that are not intended to
have bells but need a bell sound to indicated that the bell state is on or off.
42 Consult the Quantum DCC Reference Manual (Version 3) to learn how to reset different groups of CV’s.
43 “113” is QSI’s Manufacturer’s ID Number assigned by the NMRA.